A dual vacuum chamber Fourier transform mass spectrometer with rapidly interchangeable FAB, MALDI and ESI sources: Electrospray results

被引:15
作者
Gard, EE [1 ]
Green, MK [1 ]
Warren, H [1 ]
Camara, EJO [1 ]
He, F [1 ]
Penn, SG [1 ]
Lebrilla, CB [1 ]
机构
[1] LAWRENCE LIVERMORE NATL LAB, DEPT CHEM, DAVIS, CA 95616 USA
来源
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES | 1996年 / 157卷
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
electrospray; Fourier transform mass spectrometry; instrumentation; kinetic energy; collision induced dissociation;
D O I
10.1016/S0168-1176(96)04404-7
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A versatile, inexpensive electrospray interface has been constructed and installed on an external source Fourier transform mass spectrometer with a quadrupole ion guide. This interface is readily interchangeable with FAB and MALDI sources, with the main time requirement for changing being the pump-down time. A heated capillary, two skimmers and a set of Einzel lenses are used to deliver ions to the quadrupole ion guide. SIMION (Idaho National Engineering Laboratory, Idaho Falls, Idaho) was used to model ion trajectories and determine optimal dimensions. Five stages of pumping are employed, using mechanical, turbomolecular and cryopumps. A solenoid-driven shutter on the final lens blocks neutrals after injection of the ion packet. Kinetic energy distributions of both small and large biomolecular ions were investigated. For large (10(4)-10(5) Da), highly charged species, the kinetic energy distributions were quite favorable to trapping, with sharp peaks at less than 10 eV. Thus a 50 ms ion accumulation time is sufficient to obtain spectra of lysozyme with high S/N ratio. Distributions for smaller ions tended to be somewhat wider and peaked at higher energies. The spectra obtained to date illustrate the ability of the instrument to handle biomolecules ranging from bradykinin to bovine serum albumen.
引用
收藏
页码:115 / 127
页数:13
相关论文
共 31 条
[1]  
BEU SC, 1993, J AM SOC MASS SPECTR, V4, P556
[2]   COLLISION-INDUCED DISSOCIATION OF PROTON-BOUND ALCOHOL DIMERS BY FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
BURNIER, RC ;
CODY, RB ;
FREISER, BS .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1982, 104 (26) :7436-7441
[3]   A dual vacuum chamber Fourier transform mass spectrometer with rapidly interchangeable LSIMS, MALDI, and ESI sources: Initial results with LSIMS and MALDI [J].
Carroll, JA ;
Penn, SG ;
Fannin, ST ;
Wu, JY ;
Cancilla, MT ;
Green, MK ;
Lebrilla, CB .
ANALYTICAL CHEMISTRY, 1996, 68 (10) :1798-1804
[4]   DEPROTONATION REACTIONS OF MULTIPLY PROTONATED UBIQUITIN IONS [J].
CASSADY, CJ ;
WRONKA, J ;
KRUPPA, GH ;
LAUKIEN, FH .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (05) :394-400
[5]   DIRECT CHARGE NUMBER AND MOLECULAR-WEIGHT DETERMINATION OF LARGE INDIVIDUAL IONS BY ELECTROSPRAY-IONIZATION FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
CHEN, RD ;
WU, AY ;
MITCHELL, DW ;
HOFSTADLER, SA ;
ROCKWOOD, AL ;
SMITH, RD .
ANALYTICAL CHEMISTRY, 1994, 66 (22) :3964-3969
[6]   USING ELECTROSPRAY-IONIZATION FTICR MASS-SPECTROMETRY TO STUDY COMPETITIVE-BINDING OF INHIBITORS TO CARBONIC-ANHYDRASE [J].
CHENG, XH ;
CHEN, RD ;
BRUCE, JE ;
SCHWARTZ, BL ;
ANDERSON, GA ;
HOFSTADLER, SA ;
GALE, DC ;
SMITH, RD ;
GAO, JM ;
SIGAL, GB ;
MAMMEN, M ;
WHITESIDES, GM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1995, 117 (34) :8859-8860
[7]   ELECTROSPRAY IONIZATION MAGNETIC-SECTOR MASS-SPECTROMETRY - CALIBRATION, RESOLUTION, AND ACCURATE MASS MEASUREMENTS [J].
CODY, RB ;
TAMURA, J ;
MUSSELMAN, BD .
ANALYTICAL CHEMISTRY, 1992, 64 (14) :1561-1570
[8]   FALSE POSITIVES AND THE DETECTION OF CYCLODEXTRIN INCLUSION COMPLEXES BY ELECTROSPRAY MASS-SPECTROMETRY [J].
CUNNIFF, JB ;
VOUROS, P .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1995, 6 (05) :437-447
[9]   OBSERVATION OF NONCOVALENT ENZYME SUBSTRATE AND ENZYME PRODUCT COMPLEXES BY ION-SPRAY MASS-SPECTROMETRY [J].
GANEM, B ;
LI, YT ;
HENION, JD .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (20) :7818-7819
[10]  
GARD E, 1995, 43 ASMS C MASS SPECT