Multichannel amperometric detection system for liquid chromatography to assay the thiols in human whole blood using the platinum microelectrodes chemically modified by copper tetraaminophthalocyanine

被引:65
作者
Zhang, S
Sun, WL
Xian, YZ
Zhang, W
Jin, LT [1 ]
Yamamoto, K
Tao, SG
Jin, JY
机构
[1] E China Normal Univ, Dept Chem, Shanghai 200062, Peoples R China
[2] BAS Co Ltd, Sumida Ku, Tokyo 131, Japan
[3] Gifu Univ, Fac Engn, Dept Chem, Gifu 50111, Japan
基金
中国博士后科学基金;
关键词
liquid chromatography; multichannel amperometric detection system; chemically modified electrode; microdialysis sampling; copper tetraaminophthalocyanine;
D O I
10.1016/S0003-2670(99)00467-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The fabrication and application of a novel multichannel amperometric detection system (MADS) with chemically modified microelectrodes (CMEs) for liquid chromatography (LC) are described. These CMEs are based on the immobilization of copper tetraaminophthalocyanine(CuTAPc) on platinum (Pt) microelectrodes by cyclic voltammetry (CV). The CMEs show good catalytic activity oxidation of several analytes including thiocompounds. With the multichannel amperometric detection system (MADS) coupled to LC, a three-dimensional hydrodynamic voltammogram (3D HDV) (i.e. current as a function of time and potential) is obtained. The optimum detection potentials of thiocompounds and other analytes at the CMEs are easy to find. The novel multichannel amperometric detector with CMEs shows good stability and reproducibility in detecting the thiocompounds and other analytes in LC. The linear ranges cover over three orders of magnitude and the limits of detection are 10 pmol for cysteine, 16 pmol for glutathione, 16 pmol for N-acetylcysteine, 10 pmol for ascorbic acid and 16 pmol for uric acid. The application of this method with microdialysis sampling and normal sampling in human whole blood assay is successful, The method of LC-MADS with microdialysis sampling is more useful to assay the compounds in the biological matrix. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:213 / 221
页数:9
相关论文
共 22 条
[1]   SYNTHESIS AND STRUCTURAL STUDIES OF METAL(II) 4,9,16,23-PHTHALOCYANINE TETRAAMINES [J].
ACHAR, BN ;
FOHLEN, GM ;
PARKER, JA ;
KESHAVAYYA, J .
POLYHEDRON, 1987, 6 (06) :1463-1467
[2]   THE DIALYSIS ELECTRODE - A NEW METHOD FOR INVIVO MONITORING [J].
ALBERY, WJ ;
BOUTELLE, MG ;
GALLEY, PT .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1992, (12) :900-901
[3]   MULTICHANNEL ELECTROCHEMICAL DETECTION WITH A MICROELECTRODE ARRAY IN FLOWING STREAMS [J].
AOKI, A ;
MATSUE, T ;
UCHIDA, I .
ANALYTICAL CHEMISTRY, 1992, 64 (01) :44-49
[4]   FLOW-INJECTION AMPEROMETRIC DETERMINATION OF INSULIN BASED UPON ITS OXIDATION AT A MODIFIED ELECTRODE [J].
COX, JA ;
GRAY, TJ .
ANALYTICAL CHEMISTRY, 1989, 61 (21) :2462-2464
[5]  
GUNASINHAM H, 1988, ELECTROANALYTICAL CH, V15
[6]   DETERMINATION OF CYSTEINE AND GLUTATHIONE IN PLASMA AND BLOOD BY LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION USING A CHEMICALLY MODIFIED ELECTRODE CONTAINING COBALT PHTHALOCYANINE [J].
HALBERT, MK ;
BALDWIN, RP .
JOURNAL OF CHROMATOGRAPHY, 1985, 345 (01) :43-49
[7]   AMPEROMETRIC DETECTION OF THIOPURINES IN BLOOD-PLASMA WITH A COBALT-PHTHALOCYANINE CHEMICALLY MODIFIED ELECTRODE AFTER LIQUID-CHROMATOGRAPHY [J].
HALBERT, MK ;
BALDWIN, RP .
ANALYTICA CHIMICA ACTA, 1986, 187 :89-97
[8]   LIQUID-CHROMATOGRAPHY WITH ELECTROCATALYTIC DETECTION OF CYSTEINE, N-ACETYLCYSTEINE AND GLUTATHIONE BY A PRUSSIAN BLUE FILM-MODIFIED ELECTRODE [J].
HOU, WY ;
WANG, EK .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1991, 316 (1-2) :155-163
[9]   Selective electrochemical detection using a split disk array electrode in a thin-layer radial flow system [J].
Iwasaki, Y ;
Niwa, O ;
Morita, M ;
Tabei, H ;
Kissinger, PT .
ANALYTICAL CHEMISTRY, 1996, 68 (21) :3797-3800
[10]  
KONG TF, 1997, ANAL CHIM ACTA, V356, P245