Effect of potential confounding factors on the thrombolysis in myocardial infarction (TIMI) trial frame count and its reproducibility

被引:73
作者
Abaci, A [1 ]
Oguzhan, A [1 ]
Eryol, NK [1 ]
Ergin, A [1 ]
机构
[1] Erciyes Univ, Tip Fak Kardiyol Anabilim Dali, Dept Cardiol, Sch Med, TR-38039 Kayseri, Turkey
关键词
angiography; blood flow; coronary disease; nitroglycerin;
D O I
10.1161/01.CIR.100.22.2219
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The potential factors that introduce variability into TIMI frame count (TFC) have not been systematically investigated. The goal of this study was to determine if nitrate use, dye injection rate, catheter size, the phase of the cardiac cycle in which dye is injected, or heart rate affect the TFC and to investigate the reproducibility of the TFC. Methods and Results-The dye injection rate was increased 1 mL/s, and angiography was repeated. A coronary angiogram was taken first with an 8F catheter and then with a 6F catheter. After taking angiograms, intracoronary nitrate was given to the patient, and the second angiography was performed. Basal heart rate was increased 20 beats/min, and angiography was repeated, Dye injection was performed at the beginning of systole and diastole. The TFC was not significantly changed by increasing the dye injection rate (P=0.467) or by changing catheter size (P=0.693). Nitrate administration significantly increased the TFC from 26.4+/-11.9 to 32.8+/-13.3 frames (P<0.001). Dye injection at the beginning of diastole significantly decreased the TFC from 30.1+/-8.8 to 24.4+/-7.9 frames (P<0.001) for the left coronary artery and from 24.16+/-4.49 to 21.24+/-4.45 frames (P<0.001) for the right coronary artery, Increasing heart rate significantly decreased the TFC from 30.4+/-6.1 to 25.3+/-7.2 frames (P<0.001). Intraobserver and interobserver reproducibility of the TFC was good (mean difference, 1.33+/-1.24 and 2.57+/-1.72 frames, respectively). Conclusions-Nitrate use, heart rate, and the phase of the cardiac cycle in which dye is injected had significant effects on the TFC, Therefore, studies comparing TFC need to consider these factors, and the use of nitrates should be either standardized or randomized.
引用
收藏
页码:2219 / 2223
页数:5
相关论文
共 17 条
  • [1] EFFECT OF INTRACORONARY INJECTION OF CONTRAST-MEDIUM UPON CORONARY BLOOD-FLOW
    BASSAN, M
    GANZ, W
    MARCUS, HS
    SWAN, HJC
    [J]. CIRCULATION, 1975, 51 (03) : 442 - 445
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] Impact of injection rate on the Thrombolysis In Myocardial Infarction (TIMI) trial frame count
    Dodge, JT
    Rizzo, M
    Nykiel, M
    Altmann, J
    Hobkirk, K
    Brennan, M
    Gibson, CM
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (10) : 1268 - +
  • [4] A new densitometric approach to the assessment of mean coronary flow
    Dorsaz, PA
    Doriot, PA
    Dorsaz, L
    Chatelain, P
    Rutishauser, W
    [J]. INVESTIGATIVE RADIOLOGY, 1997, 32 (04) : 198 - 204
  • [5] Techniques in the angiographic analysis of coronary flow: Past, present, and future
    Dotani, I
    Dodge, JT
    Goel, M
    AlMousa, EN
    McLean, C
    Rizzo, M
    Ryan, K
    Vatner, R
    Marble, SJ
    Daley, WL
    Gibson, CM
    [J]. JOURNAL OF INTERVENTIONAL CARDIOLOGY, 1996, 9 (06) : 429 - 444
  • [6] VALIDATION OF A DOPPLER GUIDE WIRE FOR INTRAVASCULAR MEASUREMENT OF CORONARY-ARTERY FLOW VELOCITY
    DOUCETTE, JW
    CORL, PD
    PAYNE, HM
    FLYNN, AE
    GOTO, M
    NASSI, M
    SEGAL, J
    [J]. CIRCULATION, 1992, 85 (05) : 1899 - 1911
  • [7] Abnormal coronary flow in infarct arteries 1 year after myocardial infarction is predicted at 4 weeks by corrected thrombolysis in myocardial infarction (TIMI) frame count and stenosis severity
    French, JK
    Ellis, CJ
    Webber, BJ
    Williams, BF
    Amos, DJ
    Ramanathan, K
    Whitlock, RML
    White, HD
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (06) : 665 - 671
  • [8] TIMI frame count: A quantitative method of assessing coronary artery flow
    Gibson, CM
    Cannon, CP
    Daley, WL
    Dodge, JT
    Alexander, B
    Marble, SJ
    McCabe, CH
    Raymond, L
    Fortin, T
    Poole, WK
    Braunwald, E
    [J]. CIRCULATION, 1996, 93 (05) : 879 - 888
  • [9] Angioplasty guidewire velocity: A new simple method to calculate absolute coronary blood velocity and flow
    Gibson, CM
    Dodge, JT
    Goel, M
    AlMousa, EN
    Rizzo, M
    McLean, C
    Ryan, K
    Sparano, A
    Marble, SJ
    Daley, WL
    Cannon, CP
    Antman, EM
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (12) : 1536 - 1539
  • [10] ULTRASONIC PULSED DOPPLER SYSTEM FOR MEASURING BLOOD-FLOW IN SMALL VESSELS
    HARTLEY, CJ
    COLE, JS