A dosimetric comparison of fan-beam intensity modulated radiotherapy with gamma knife stereotactic radiosurgery for treating intermediate intracranial lesions

被引:39
作者
Ma, LJ
Xia, P
Verhey, LJ
Boyer, AL
机构
[1] Univ Maryland, Sch Med, Dept Radiat Oncol, Baltimore, MD 21201 USA
[2] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94143 USA
[3] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1999年 / 45卷 / 05期
关键词
intensity modulated radiotherapy; multileaf collimator; gamma knife; stereotactic radiotherapy; radiosurgery;
D O I
10.1016/S0360-3016(99)00340-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To compare and evaluate treatment plans for the fan-beam intensity modulated radiotherapy and the Gamma Knife radiosurgery for treating medium-size intracranial lesions (range 4-25 cm(3)). Methods and Materials: Treatment plans were developed for the Leksell Gamma Knife and a fan-beam inverse treatment planning system for intensity modulated radiotherapy. Treatment plan comparisons were carried out using dose-volume histogram (DVH), tissue-volume ratio (TVR), and maximum dose to the prescription dose (MDPD) ratio. The study was carried out for both simulated targets and clinical targets with irregular shapes and at different locations. Results: The MDPD ratio was significantly greater for the Gamma Knife plans than for the fan-beam IMRT plans. The Gamma Knife plans produced equivalent TVR values to the fan-beam IMRT plans. Based on the DVH comparison, the fan-beam IMRT delivered significantly more dose to the normal brain tissue than the Gamma Knife. The results of the comparison were found to be insensitive to the target locations. Conclusion: The Gamma Knife is better than the fan-beam IMRT in sparing normal brain tissue while producing equivalent tumor dose conformity for treating medium-size intracranial lesions. However, the target dose homogeneity is significantly better for the fan-beam IMRT than for the Gamma Knife. (C) 1999 Elsevier Science Inc.
引用
收藏
页码:1325 / 1330
页数:6
相关论文
共 18 条
[1]  
BENJAMIN WC, 1997, SEMIN ONCOL, V24, P707
[2]   Modulated beam conformal therapy for head and neck tumors [J].
Boyer, AL ;
Geis, P ;
Grant, W ;
Carol, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (01) :227-236
[3]   PEACOCK(TM) - A SYSTEM FOR PLANNING AND ROTATIONAL DELIVERY OF INTENSITY-MODULATED FIELDS [J].
CAROL, MP .
INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 1995, 6 (01) :56-61
[4]   Radiosurgery for skull base malignancies and nasopharyngeal carcinoma [J].
Cmelak, AJ ;
Cox, RS ;
Adler, JR ;
Fee, WE ;
Goffinet, DR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (05) :997-1003
[5]  
Kramer B A, 1998, Radiat Oncol Investig, V6, P18, DOI 10.1002/(SICI)1520-6823(1998)6:1<18::AID-ROI3>3.3.CO
[6]  
2-J
[7]   Optimized beam planning for linear accelerator-based stereotactic radiosurgery [J].
Lu, HM ;
Kooy, HM ;
Leber, ZH ;
Ledoux, RJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (05) :1183-1189
[8]   STEREOTACTIC RADIOSURGERY - PRINCIPLES AND COMPARISON OF TREATMENT METHODS [J].
LUXTON, G ;
PETROVICH, Z ;
JOZSEF, G ;
NEDZI, LA ;
APUZZO, MLJ .
NEUROSURGERY, 1993, 32 (02) :241-259
[9]  
LUXTON G, 1995, INT J RADIAT ONCOL, V31, P653
[10]   Potential clinical efficacy of intensity-modulated conformal therapy [J].
Meeks, SL ;
Buatti, JM ;
Bova, FJ ;
Friedman, WA ;
Mendenhall, WM ;
Zlotecki, RA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (02) :483-495