Resolving stoichiometries and oligomeric states of glutamate synthase protein complexes with curve fitting and simulation of electrospray mass spectra

被引:42
作者
van Breukelen, Bas
Barendregt, Arjan
Heck, Albert J. R.
van den Heuvel, Robert H. H.
机构
[1] Univ Utrecht, Bijvoet Ctr Biomol Res, NL-3584 CA Utrecht, Netherlands
[2] Univ Utrecht, Utrecht Inst Pharmaceut Sci, NL-3584 CA Utrecht, Netherlands
关键词
D O I
10.1002/rcm.2620
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A complicating factor in analyzing electrospray ionization mass spectra of intact macromolecular heterogeneous protein complexes is the potential overlap of ions from different species present in solution. Therefore, it is often not possible to assign all ion signals. With the aim of allowing the more efficient and comprehensive analysis of very complex mass spectra of intact heterogeneous protein complexes we developed a software program: SOMMS. The program uses simple user input parameters together with Gaussian curve fitting to simulate putative mass spectra of protein (sub)complexes within a specified charge state window. In addition, the program can simulate spectra for heterogeneous protein complexes using bi- and multinomial distributions and it can calculate zero-charge spectra and relatively quantify the abundance of each component in a mixture. As a proof of concept we analyzed the complex mass spectra of a-glutamate synthase and alpha beta-glutantate synthase from Azosprillum brasilense. Using our program we could determine that a-glutamate synthase is in equilibrium between its dimeric, tetrameric, hexameric and dodecameric conformation, whereas cifl-glutamate synthase forms up to 15 different heterooligomeric assemblies composed of alpha- and beta-subunits. Thus, SOMMS allows resolving stoichiometries and oligomeric states of protein complexes even from very complicated mass spectra. These complexes could not be assigned by using maximum entropy calculations. We compared our mass spectrometry data on glutamate synthases with available X-ray, small-angle X-ray scattering and size-exclusion chromatography data. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:2490 / 2496
页数:7
相关论文
共 20 条
[1]   Cross-talk and ammonia channeling between active centers in the unexpected domain arrangement of glutamate synthase [J].
Binda, C ;
Bossi, RT ;
Wakatsuki, S ;
Arzt, S ;
Coda, A ;
Curti, B ;
Vanoni, MA ;
Mattevi, A .
STRUCTURE, 2000, 8 (12) :1299-1308
[2]   Collisional cooling of large ions in electrospray mass spectrometry [J].
Chernushevich, IV ;
Thomson, BA .
ANALYTICAL CHEMISTRY, 2004, 76 (06) :1754-1760
[3]  
de la Mora JF, 2000, ANAL CHIM ACTA, V406, P93
[4]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[5]   MAXIMUM-ENTROPY DECONVOLUTION IN ELECTROSPRAY MASS-SPECTROMETRY [J].
FERRIGE, AG ;
SEDDON, MJ ;
JARVIS, S .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1991, 5 (08) :374-377
[6]   THE APPLICATION OF MAXENT TO HIGH-RESOLUTION MASS-SPECTROMETRY [J].
FERRIGE, AG ;
SEDDON, MJ ;
SKILLING, J ;
ORDSMITH, N .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1992, 6 (12) :765-770
[7]   DISENTANGLING ELECTROSPRAY SPECTRA WITH MAXIMUM-ENTROPY [J].
FERRIGE, AG ;
SEDDON, MJ ;
GREEN, BN ;
JARVIS, SA ;
SKILLING, J .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1992, 6 (11) :707-711
[8]   Investigation of intact protein complexes by mass spectrometry [J].
Heck, AJR ;
van den Heuvel, RHH .
MASS SPECTROMETRY REVIEWS, 2004, 23 (05) :368-389
[9]  
Krutchinsky AN, 1998, RAPID COMMUN MASS SP, V12, P508, DOI 10.1002/(SICI)1097-0231(19980515)12:9<508::AID-RCM197>3.0.CO
[10]  
2-L