Normal fault thermal regimes: conductive and hydrothermal heat transfer surrounding the Wasatch fault, Utah

被引:47
作者
Ehlers, TA [1 ]
Chapman, DS [1 ]
机构
[1] Univ Utah, Dept Geol & Geophys, Salt Lake City, UT 84112 USA
关键词
heat flow; conductive; hydrothermal; normal fault; Wasatch; numerical model; hot spring;
D O I
10.1016/S0040-1951(99)00203-6
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
The thermal regime across an active normal fault is affected by tectonic processes of exhumation and erosion of the footwall and burial and sedimentation on the hanging wall. An enhanced thermal regime in the footwall is juxtaposed against a thermally depressed regime in the hanging wall causing significant two-dimensional (2D) heat flow. These thermal processes have been simulated with 2D numerical models and applied to the Wasatch fault of central Utah. Simulations included variable fault angles of 90 degrees, 60 degrees, and 45 degrees and a vertical displacement profile accounting for hanging wall and footwall tilt. After 20 m.y. of fault movement, 60 degrees fault, isotherms are displaced similar to 1 km on the footwall and hanging wall. Furthermore, model surface heat flow is enhanced by 25% above the footwall and depressed by 15% above the hanging wall 10 km from the fault trace; the heat flow transition has a half width of 10 km. Present-day surface heat flow was compiled for 23 sites along the Wasatch Front. Heat flow has a mean value of 92 mW/m(2) (standard deviation 25 mW/m(2)) but, unlike model predictions, does not show a discernible variation in heat flow across the fault. Part of the discrepancy between predicted and observed conductive heat flow may be caused by groundwater which recharges in the uplifted footwall, is heated in the subsurface, and discharges as thermal water along the range bounding fault or into the hanging wall valley. Flow rates and water temperatures from 29 tectonic hot springs along the Wasatch Front indicate a minimum hydrothermal thermal power loss of 90 MW or 0.24 MW per kilometer of strike along the fault. This thermal power is equivalent to a heat flow of 21 mW/m(2) captured uniformly between the range crest and range front, and discharged in hot springs. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:217 / 234
页数:18
相关论文
共 66 条
[1]  
[Anonymous], 1981, Geothermal Systems, DOI DOI 10.1093/GJI/66.3.752
[2]  
ARABASZ WJ, 1992, ASSESSMENT REGIONAL, pD1
[3]  
BARTON CM, 1979, GEOL SOC AM BULL, V90, P483, DOI 10.1130/0016-7606(1979)90<483:SHATOG>2.0.CO
[4]  
2
[5]   THE EFFECT OF UPLIFT AND DENUDATION ON UNDERGROUND TEMPERATURES [J].
BENFIELD, AE .
JOURNAL OF APPLIED PHYSICS, 1949, 20 (01) :66-70
[6]  
BIRCH F, 1950, GEOL SOC AM BULL, V61, P567, DOI 10.1130/0016-7606(1950)61[567:FOHITF]2.0.CO
[7]  
2
[8]  
BLACKETT RE, 1994, 311 UT GEOL SURV
[9]  
BLACKWELL DD, 1991, NEOTECTONICS N AM, P423
[10]   HEAT-FLOW IN THE NORTH-CENTRAL COLORADO PLATEAU [J].
BODELL, JM ;
CHAPMAN, DS .
JOURNAL OF GEOPHYSICAL RESEARCH, 1982, 87 (NB4) :2869-2884