Endovascular repair of infrarenal aortic aneurysms. Report on 4291 patients of the Eurostar database

被引:14
作者
Enzler, MA [1 ]
van Marrewijk, CJ [1 ]
Buth, J [1 ]
Harris, PL [1 ]
机构
[1] Eurostar Data Registry Ctr, European Collaborators Stent Graft Tech Abdominal, Eindhoven, Netherlands
来源
VASA-JOURNAL OF VASCULAR DISEASES | 2002年 / 31卷 / 03期
关键词
aortic aneurysm; endovascular repair; stentgraft; aortic rupture; aortic repair;
D O I
10.1024/0301-1526.31.3.167
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Endovascular repair of infrarenal aortic aneurysms. Report on 4291 patients of the Eurostar database Background: The Eurostar project is a multicentred database of the outcome of endovascular repair of infra-renal aortic aneurysms. From 1996 to March, 2002, 113 European centres of vascular surgery have contributed. The purpose of this article is to review the medium term (up to 7 years) results of endovascular aneurysm repair as reported to Eurostar . Patients and methods: Patients intended for endovascular aneurysm repair were notified to the Eurostar Data Registry Centre before treatment in order to eliminate bias due to selective reporting. The following data was collected on all patients: (1) their demographic details and the anatomical characteristics of their aneurysms, (2) details of the endovascular device used, (3) procedural complications and the immediate outcome, (4) results of contrast enhanced CT imaging at 1, 3, 6, 12, 18 and 24 months after operation and at yearly intervals thereafter, (5) all adverse events. Life table analysis was performed to determine the cumulative rates of: (1) death from all causes, (2) secondary intervention. Results: By March 2002, pre- and postoperative data of 4291 patients had been registered. The median duration of follow-up was 12 mo (range 0-96). Successful deployment was achieved in 97.8% of the patients with a perioperative (30 day) mortality of 2.4%. Early conversion to open repair occurred in 1.3%. Late rupture of the aneurysm occurred in 35 patients. The significant factors were endoleaks, graft migration and kinking. Late conversion to open repair occurred at an annual rate of approximately 2%. Risk factors (indications)for late conversion were endoleaks, graft migration and kinking. Conclusions: Endovascular repair of infra-renal aortic aneurysms using the first and second-generation devices that predominated in this study is associated with a risk of early or late failure of 3% per year, based upon an analysis of observed primary endpoints of rupture and conversion.
引用
收藏
页码:167 / 172
页数:6
相关论文
共 16 条
[1]   Reporting standards for infrarenal endovascular abdominal aortic aneurysm repair [J].
Ahn, SS ;
Rutherford, RB ;
Johnston, KW ;
May, J ;
Veith, FJ ;
Baker, JD ;
Ernst, CB ;
Moore, WS .
JOURNAL OF VASCULAR SURGERY, 1997, 25 (02) :405-410
[2]   Rupture of an abdominal aortic aneurysm after endovascular graft placement and aneurysm size reduction [J].
Alimi, YS ;
Chakfe, N ;
Rivoal, E ;
Slimane, KK ;
Valerio, N ;
Riepe, G ;
Kretz, JG ;
Juhan, C .
JOURNAL OF VASCULAR SURGERY, 1998, 28 (01) :178-183
[3]  
BECQUEMIN JP, MID TERM RESULTS 2 G
[4]  
CUYPERS P, 1999, EUR J VASC ENDOV JUN, P17
[5]   Freedom from endoleak after endovascular aneurysm repair does not equal treatment success [J].
Gilling-Smith, GL ;
Martin, J ;
Sudhindran, S ;
Gould, DA ;
McWilliams, RG ;
Bakran, A ;
Brennen, JA ;
Harris, PL .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2000, 19 (04) :421-425
[6]  
Harris P, 1999, J ENDOVASC SURG, V6, P11, DOI 10.1583/1074-6218(1999)006<0011:LASFEA>2.0.CO
[7]  
2
[8]  
Harris PL, 1997, J ENDOVASC SURG, V4, P72, DOI 10.1583/1074-6218(1997)004<0072:TNFCTO>2.0.CO
[9]  
2
[10]   Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: The EUROSTAR experience [J].
Harris, PL ;
Vallabhaneni, SR ;
Desgranges, P ;
Bacquemin, JP ;
van Marrewijk, C ;
Laheij, RJF .
JOURNAL OF VASCULAR SURGERY, 2000, 32 (04) :739-749