Technical issues for the study of the optic nerve with MRI

被引:18
作者
Barker, GJ [1 ]
机构
[1] UCL, Neurol Inst, London WC1N 3BG, England
关键词
MRI; optic nerve; fast spin echo; STIR; FLAIR; T(2); magnetization transfer; diffusion tensor imaging;
D O I
10.1016/S0022-510X(99)00271-3
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The optic nerve is technically challenging to investigate with Magnetic Resonance Imaging due to its small size, the effect of surrounding cerebrospinal fluid and lipid, and the presence of nearby bony structures. With careful optimization it is possible to obtain high quality T(1) and T(2) weighted images for qualitative assessment, however, although quantitative measurements of parameters such as relaxation times, magnetization transfer ratio and apparent diffusion coefficient may be problematic. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:S13 / S16
页数:4
相关论文
共 16 条
[1]   THE LONGSTANDING MS LESION - A QUANTITATIVE MRI AND ELECTRON-MICROSCOPIC STUDY [J].
BARNES, D ;
MUNRO, PMG ;
YOUL, BD ;
PRINEAS, JW ;
MCDONALD, WI .
BRAIN, 1991, 114 :1271-1280
[2]   MR IMAGING - CLINICAL USE OF THE INVERSION RECOVERY SEQUENCE [J].
BYDDER, GM ;
YOUNG, IR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) :659-675
[3]   Magnetic resonance imaging in the differential diagnosis and monitoring of the treatment of multiple sclerosis [J].
Filippi, M ;
Miller, DH .
CURRENT OPINION IN NEUROLOGY, 1996, 9 (03) :178-186
[4]  
Gass A, 1996, NEURORADIOLOGY, V38, P317
[5]   HIGH-RESOLUTION MAGNETIC-RESONANCE-IMAGING OF THE ANTERIOR VISUAL PATHWAY IN PATIENTS WITH OPTIC NEUROPATHIES USING FAST SPIN-ECHO AND PHASED-ARRAY LOCAL COILS [J].
GASS, A ;
BARKER, GJ ;
MACMANUS, D ;
SANDERS, M ;
RIORDANEVA, P ;
TOFTS, PS ;
THORPE, J ;
MCDONALD, WI ;
MOSELEY, IF ;
MILLER, DH .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1995, 58 (05) :562-569
[6]   H-1-NMR CHEMICAL-SHIFT SELECTIVE (CHESS) IMAGING [J].
HAASE, A ;
FRAHM, J ;
HANICKE, W ;
MATTHAEI, D .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (04) :341-344
[7]   DESIGN AND IMPLEMENTATION OF MAGNETIZATION TRANSFER PULSE SEQUENCES FOR CLINICAL USE [J].
HAJNAL, JV ;
BAUDOUIN, CJ ;
OATRIDGE, A ;
YOUNG, IR ;
BYDDER, GM .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (01) :7-18
[8]   USE OF FLUID ATTENUATED INVERSION RECOVERY (FLAIR) PULSE SEQUENCES IN MRI OF THE BRAIN [J].
HAJNAL, JV ;
BRYANT, DJ ;
KASUBOSKI, L ;
PATTANY, PM ;
DECOENE, B ;
LEWIS, PD ;
PENNOCK, JM ;
OATRIDGE, A ;
YOUNG, IR ;
BYDDER, GM .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (06) :841-844
[9]   Diffusion-weighted imaging of the human optic nerve: A new approach to evaluate optic neuritis in multiple sclerosis [J].
Iwasawa, T ;
Matoba, H ;
Ogi, A ;
Kurihara, H ;
Saito, K ;
Yoshida, T ;
Matsubara, S ;
Nozaki, A .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (03) :484-491
[10]   STIR SEQUENCES IN NMR IMAGING OF THE OPTIC-NERVE [J].
JOHNSON, G ;
MILLER, DH ;
MACMANUS, D ;
TOFTS, PS ;
BARNES, D ;
DUBOULAY, EPGH ;
MCDONALD, WI .
NEURORADIOLOGY, 1987, 29 (03) :238-245