High-performance liquid chromatographic assay for common sunscreening agents in cosmetic products, bovine serum albumin solution and human plasma

被引:55
作者
Jiang, R
Hayden, CGJ
Prankerd, RJ
Roberts, MS
Benson, HAE
机构
[1] UNIV QUEENSLAND,DEPT PHARM,BRISBANE,QLD 4072,AUSTRALIA
[2] UNIV QUEENSLAND,DEPT MED,BRISBANE,QLD 4072,AUSTRALIA
来源
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS | 1996年 / 682卷 / 01期
关键词
2-ethylhexyl-p-dimethyl aminobenzoate; 2-ethylhexyl-p-methoxycinnamate 4-tert-butyl-4'-methoxydibenzoylmethane; oxybenzone; octylsalicylate;
D O I
10.1016/0378-4347(96)00063-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper reports the development of a reversed-phase high-performance liquid chromatographic assay for quantifying five of the most common sunscreen agents, namely 2-ethylhexyl-p-dimethyl aminobenzoate (Escalol 507), 2-ethylhexyl-p-methoxycinnamate (Parsol MCX); 4-tert.-butyl-4'-methoxydibenzoylmethane (Parsol 1789), 2-hydroxy-4-methoxybenzophenone-3 (oxybenzone) and 2-ethylhexyl-salicylate (octylsalicylate). The assay permits analysis of the sunscreen agents in formulations and in biological fluids, including bovine serum albumin (BSA) solution, a common additive to in vitro skin diffusion cell receptor fluids, as well as human plasma. Separation was achieved using an ODS C-18 column with a methanol-water (88:12) mobile phase. The analytes were detected by ultraviolet light absorption at a wavelength of 315 nm. The assay was linear with minimum detectable limits, calculated as greater than 3-times the baseline noise level: for oxybenzone and Escalol 507, 0.05 mu g/ml; for Parsol 1789 and Parsol MCX, 0.1 mu g/ml; for octylsalicylate, 1 mu g/ml. Recoveries from both plasma and 2% BSA were within the range 89-107%. The inter- and intra-day coefficients of variation for the five agents were not more than 4% at the upper end of the linear range and not more than 10% at the lower end. Preliminary stability studies of the sunscreen agents in a commercial product and in two diffusion cell receptor fluids were also conducted.
引用
收藏
页码:137 / 145
页数:9
相关论文
共 18 条
[1]   DEVELOPMENT AND VALIDATION OF A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF BENZOPHENONE-3 IN RATS [J].
ABDELNABI, IM ;
KADRY, AM ;
DAVIS, RA ;
ABDELRAHMAN, MS .
JOURNAL OF APPLIED TOXICOLOGY, 1992, 12 (04) :255-259
[2]  
Aberturas R, 1987, Boll Chim Farm, V126, P208
[3]  
ALLEN HB, 1980, CUTIS, V26, P254
[4]   METHODS FOR INVITRO PERCUTANEOUS-ABSORPTION STUDIES .3. HYDROPHOBIC COMPOUNDS [J].
BRONAUGH, RL ;
STEWART, RF .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1984, 73 (09) :1255-1258
[5]  
BRUZE M, 1990, PHOTODERMATOL PHOTO, V7, P106
[6]  
CALLEN JP, 1990, DERMATOL CLIN, V8, P355
[7]   PREDICTION OF SKIN PERMEATION OF HIGHLY LIPOPHILIC COMPOUNDS - INVITRO MODEL WITH A MODIFIED RECEPTOR PHASE [J].
DALPOZZO, A ;
LIGGERI, E ;
DELUCCA, C ;
CALABRESE, G .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1991, 70 (03) :219-223
[8]   DETERMINATION OF SUNSCREEN COMPOUNDS IN TOPICAL SUNSCREEN PRODUCTS [J].
DINUNZIO, JE ;
GADDE, RR .
JOURNAL OF CHROMATOGRAPHY, 1990, 519 (01) :117-124
[9]  
FLINDTHANSEN H, 1988, PHOTODERMATOLOGY, V5, P257
[10]  
FOOT G, 1993, AUST J PUBLIC HEALTH, V17, P209