MRI of the kidney and urinary tract

被引:8
作者
Israel, Gary M. [1 ]
机构
[1] Yale Univ, Sch Med, Dept Diagnost Radiol, New Haven, CT 06520 USA
关键词
MRI; kidney; urinary tract; neoplasm; cyst;
D O I
10.1002/jmri.20700
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
MRI of the kidney and urinary tract has evolved with advancements in MR technology combined with further radiologic experience. A combination of simple pulse sequences and the use of gadolinium (Gd) allow a comprehensive evaluation of the genitourinary system and facilitate the detection and accurate characterization of renal and urinary tract masses. In this review an MRI technique used to evaluate the kidneys and urinary tract is presented with an emphasis on the characterization of renal masses.
引用
收藏
页码:725 / 734
页数:10
相关论文
共 50 条
[1]   Complex renal cysts: Findings on MR imaging [J].
Balci, NC ;
Semelka, RC ;
Patt, RH ;
Dubois, D ;
Freeman, JA ;
Gomez-Caminero, A ;
Woosley, JT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (06) :1495-1500
[2]  
BOSNIAK MA, 1993, UROL CLIN N AM, V20, P217
[3]  
BOSNIAK MA, 1986, RADIOLOGY, V158, P1
[4]   Transitional cell carcinoma of the upper urinary tract: Spectrum of imaging findings [J].
Browne, RFJ ;
Meehan, CP ;
Colville, J ;
Power, R ;
Torreggiani, WC .
RADIOGRAPHICS, 2005, 25 (06) :1609-1627
[5]   COMPUTED-TOMOGRAPHY OF RENAL LYMPHOMA [J].
COHAN, RH ;
DUNNICK, NR ;
LEDER, RA ;
BAKER, ME .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (06) :933-938
[6]   Renal-cell carcinoma [J].
Cohen, HT ;
McGovern, FJ .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 353 (23) :2477-2490
[7]   Diffusion-weighted MRI in the evaluation of renal lesions: preliminary results [J].
Cova, M ;
Squillaci, E ;
Stacul, F ;
Manenti, G ;
Gava, S ;
Simonetti, G ;
Pozzi-Mucelli, R .
BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (922) :851-857
[8]   Arterial spin labeling blood flow magnetic resonance imaging for the characterization of metastatic renal cell carcinoma [J].
De Bazelaire, C ;
Rofsky, NM ;
Duhamel, G ;
Michaelson, MD ;
George, D ;
Alsop, DC .
ACADEMIC RADIOLOGY, 2005, 12 (03) :347-357
[9]   Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector [J].
Earls, JP ;
Rofsky, NM ;
DeCorato, DR ;
Krinsky, GA ;
Weinreb, JC .
RADIOLOGY, 1996, 201 (03) :705-710
[10]   RENAL MASSES - EVALUATION WITH GRADIENT-ECHO GD-DTPA ENHANCED DYNAMIC MR IMAGING [J].
EILENBERG, SS ;
LEE, JKT ;
BROWN, JJ ;
MIROWITZ, SA ;
TARTAR, VM .
RADIOLOGY, 1990, 176 (02) :333-338