Semi-automated 96-well liquid-liquid extraction for quantitation of drugs in biological fluids

被引:52
作者
Zhang, NY [1 ]
Hoffman, KL [1 ]
Li, WL [1 ]
Rossi, DT [1 ]
机构
[1] Warner Lambert Parke Davis, Parke Davis Pharmaceut Res, Bioanalyt Core Grp, Dept Pharmacokinet Dynam & Metab, Ann Arbor, MI 48105 USA
关键词
96-well format; LC/MS/MS; plasma; parallel sample processing;
D O I
10.1016/S0731-7085(99)00247-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A semi-automated liquid-liquid extraction (LLE) technique for biological fluid sample preparation was introduced for the quantitation of four drugs in rat plasma. All liquid transferring during the sample preparation was automated using a Tomtec Quadra 96 Model 320 liquid handling robot, which processed up to 96 samples in parallel. The samples were either in 96-deep-well plate or tube-rack format. One plate of samples can be prepared in approximately 1.5 h, and the 96-well plate is directly compatible with the autosampler of an LC/MS system. Selection of organic solvents and recoveries are discussed. Also, precision, relative error, linearity and quantitation of the semi automated LLE method are estimated for four example drugs using LC/MS/MS with a multiple reaction monitoring (MRM) approach. The applicability of this method and future directions are evaluated. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:131 / 138
页数:8
相关论文
共 12 条
[1]   EQUATIONS FOR CALCULATION OF CHROMATOGRAPHIC FIGURES OF MERIT FOR IDEAL AND SKEWED PEAKS [J].
FOLEY, JP ;
DORSEY, JG .
ANALYTICAL CHEMISTRY, 1983, 55 (04) :730-737
[2]   TRACE QUANTITATION OF THE NOVEL CHOLINESTERASE INHIBITOR IN HUMAN PLASMA BY CAPILLARY GAS-CHROMATOGRAPHY ION-TRAP MASS-SPECTROMETRY [J].
HOFFMAN, KL ;
ROSSI, DT ;
WRIGHT, DS .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1995, 13 (08) :979-985
[3]  
Hoffman KL, 1996, LAB ROBOTICS AUTOMAT, V8, P237, DOI 10.1002/(SICI)1098-2728(1996)8:4<237::AID-LRA6>3.0.CO
[4]  
2-1
[5]  
HUANG H, 1998, J PHARM BIOMED ANAL, V19, P613
[6]  
Larsen B. S., 1998, MASS SPECTROMETRY BI
[7]  
MAJORS RE, 1993, LC GC-MAG SEP SCI, V11, P336
[8]   Automated sample preparation for drugs in plasma using a solid-phase extraction workstation [J].
Parker, TD ;
Surendran, N ;
Stewart, BH ;
Rossi, DT .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (4-5) :851-861
[9]  
ROSSI D, 1999, IN PRESS J CHROMATOG, V875
[10]  
Simpson H, 1998, RAPID COMMUN MASS SP, V12, P75, DOI 10.1002/(SICI)1097-0231(19980131)12:2<75::AID-RCM112>3.0.CO