Design, Implementation, and Field Testing of a Portable Fluorescence- Based Vapor Sensor

被引:22
作者
Aernecke, Matthew J. [1 ]
Guo, Jian [2 ]
Sonkusale, Sameer [2 ]
Walt, David R. [1 ]
机构
[1] Tufts Univ, Dept Chem, Medford, MA 02155 USA
[2] Tufts Univ, Dept Elect & Comp Engn, Medford, MA 02155 USA
关键词
ELECTRONIC NOSE SYSTEM; HIGH-SPEED; ARRAYS; GAS; DISCRIMINATION; RECOGNITION; INFORMATION; TECHNOLOGY; AIR;
D O I
10.1021/ac900505p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The design and implementation of a portable fluorescence-based vapor sensing system are described. The system incorporates previously developed microsensor array technology into a compact, low-power device capable of collecting and delivering ambient vapor samples to the array while monitoring and recording the fluorescent responses of the sensors. The sensors respond differentially when exposed to a sample vapor and, when processed using a support vector machine (SVM) pattern recognition algorithm, are shown to discriminate between three classes of petroleum distillates. The system was characterized using sample vapors prepared under several different conditions in three sensing scenarios. The first scenario demonstrates the basic operational capability of the device in the field by presenting high concentration vapors to the array. The second scenario introduces the potential for a greater degree of variability in both sample vapor concentration and composition in an effort to emulate real-world sensing conditions. The third scenario uses an on-board trained pattern recognition algorithm to identify unknown vapors as their responses are collected. The device demonstrated high classification accuracy throughout the field tests and is capable of improving its classification accuracy when challenged with samples presented under variable ambient conditions by enhancing the signal-to-noise ratio of the array response.
引用
收藏
页码:5281 / 5290
页数:10
相关论文
共 44 条
[1]  
AERNECKE MJ, J FORENSIC IN PRESS
[2]   Cross-reactive chemical sensor arrays [J].
Albert, KJ ;
Lewis, NS ;
Schauer, CL ;
Sotzing, GA ;
Stitzel, SE ;
Vaid, TP ;
Walt, DR .
CHEMICAL REVIEWS, 2000, 100 (07) :2595-2626
[3]   Information coding in artificial olfaction multisensor arrays [J].
Albert, KJ ;
Walt, DR .
ANALYTICAL CHEMISTRY, 2003, 75 (16) :4161-4167
[4]   Field-deployable sniffer for 2,4-dinitrotoluene detection [J].
Albert, KJ ;
Myrick, ML ;
Brown, SB ;
James, DL ;
Milanovich, FP ;
Walt, DR .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (15) :3193-3200
[5]   Optical multibead arrays for simple and complex odor discrimination [J].
Albert, KJ ;
Walt, DR ;
Gill, DS ;
Pearce, TC .
ANALYTICAL CHEMISTRY, 2001, 73 (11) :2501-2508
[6]   High-speed fluorescence detection of explosives-like vapors [J].
Albert, KJ ;
Walt, DR .
ANALYTICAL CHEMISTRY, 2000, 72 (09) :1947-1955
[7]   Electronic nose based on the polymer coated SAW sensors array for the warfare agent simulants classification [J].
Alizadeh, T. ;
Zeynali, S. .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 129 (01) :412-423
[8]   Microbead chemical switches: An approach to detection of reactive organophosphate chemical warfare agent vapors [J].
Bencic-Nagale, S ;
Sternfeld, T ;
Walt, DR .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (15) :5041-5048
[9]   Extending the longevity of fluorescence-based sensor arrays using adaptive exposure [J].
Bencic-Nagale, S ;
Walt, DR .
ANALYTICAL CHEMISTRY, 2005, 77 (19) :6155-6162
[10]   Electroosmotic Flow-Based Pump for Liquid Chromatography on a Planar Microchip [J].
Borowsky, Joseph F. ;
Giordano, Braden C. ;
Lu, Qin ;
Terray, Alex ;
Collins, Greg E. .
ANALYTICAL CHEMISTRY, 2008, 80 (21) :8287-8292