Arterial pulse wave analysis: An accurate means of determining cardiac output in children

被引:27
作者
Kim, Jeffrey J. [1 ]
Dreyer, Jeffrey [1 ]
Chang, Anthony C. [1 ]
Breinholt, John P., III [1 ]
Grifka, Ronald G. [1 ]
机构
[1] Texas Childrens Hosp, Baylor Coll Med, Dept Pediat, Pediat Cardiol Sect, Houston, TX 77030 USA
关键词
D O I
10.1097/01.PCC.0000243723.47105.A2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Cardiac output is a useful measure of myocardial performance, Standard methods of determining cardiac output are not without risk and can be problematic in children. Arterial pulse wave analysis (PulseCO), a novel, minimally invasive cardiac output determination technique, offers the advantage of continuous monitoring, convenience, and low risk. This technique has not been validated in children. The purpose of this study was to validate PulseCO as an accurate means of noninvasively determining real-time cardiac output in children. Design: Prospective, single-center evaluation. Setting: Children's hospital. Patients: Any child with a structurally normal heart, undergoing hemodynamic evaluation in the cardiac catheterization laboratory, was included. Interventions: A prograde right heart catheterization was performed, and cardiac output was determined using the thermodilution technique, via placement of a pulmonary arterial catheter. Measurements and Main Results: Thermodilution results were compared with continuous real-time cardiac output measurements obtained with the PulseCO system, and they were then analyzed by standard correlation techniques and Bland-Altman analysis. Twenty patients were evaluated with a median age of 10.5 yrs and a median weight of 25 kg. The mean thermodilution cardiac index was 3.3 +/- 0.9 L/min/m(2), whereas the mean PulseCO cardiac index was 3.1 +/- 0.9 L/min/m(2). Standard Pearson correlation tests revealed a correlation coefficient of .94 (p < .001). Bland-Altman analysis revealed excellent clinical agreement with a mean difference of 0.19 L/min/m(2) and a precision of 0.28 L/min/m(2) at 2 SD. Conclusions: Arterial pulse wave analysis by the PulseCO system provides a novel, minimally invasive method of determining real-time cardiac output in children.
引用
收藏
页码:532 / 535
页数:4
相关论文
共 16 条
[1]   A RANDOMIZED CLINICAL-TRIAL OF THE EFFECT OF DELIBERATE PERIOPERATIVE INCREASE OF OXYGEN DELIVERY ON MORTALITY IN HIGH-RISK SURGICAL PATIENTS [J].
BOYD, O ;
GROUNDS, RM ;
BENNETT, ED .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1993, 270 (22) :2699-2707
[2]   A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques [J].
Critchley, LAH ;
Critchley, JAJH .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) :85-91
[3]  
Hamilton TT, 2002, ANN THORAC SURG, V74, pS1408
[4]   Mortality and the nature of metabolic acidosis in children with shock [J].
Hatherill, M ;
Waggie, Z ;
Purves, L ;
Reynolds, L ;
Argent, A .
INTENSIVE CARE MEDICINE, 2003, 29 (02) :286-291
[5]  
HELLER LB, 2002, M SOC CARD AN APR 21
[6]  
HOFFMAN G, 2005, PEDIAT CARD SURG ANN, V8, P12
[7]  
Jonas Max M, 2002, Curr Opin Crit Care, V8, P257, DOI 10.1097/00075198-200206000-00010
[8]   Equipment review:: An appraisal of the LiDCO™plus method of measuring cardiac output [J].
Pearse, RM ;
Ikram, K ;
Barry, J .
CRITICAL CARE, 2004, 8 (03) :190-193
[9]   TIMING AND PREDICTORS OF DEATH IN PEDIATRIC-PATIENTS WITH MULTIPLE ORGAN SYSTEM FAILURE [J].
PROULX, F ;
GAUTHIER, M ;
NADEAU, D ;
LACROIX, J ;
FARRELL, CA .
CRITICAL CARE MEDICINE, 1994, 22 (06) :1025-1031
[10]  
Rhodes Andrew, 2004, Crit Care Med, V32, pS448, DOI 10.1097/01.CCM.0000145945.39002.8D