Stationary Frame Current Control Evaluations for Three-Phase Grid-Connected Inverters with PVR-based Active Damped LCL Filters

被引:13
作者
Han, Yang [1 ]
Shen, Pan [1 ]
Guerrero, Josep M. [1 ]
机构
[1] Univ Elect Sci & Technol China, Sch Mechatron Engn, Dept Power Elect, Chengdu 610054, Peoples R China
基金
中国国家自然科学基金;
关键词
Active damping; LCL filter; PVR-AD scheme; Stability; Synchronous frame equivalent PI; VOLTAGE-SOURCE INVERTERS; STEADY-STATE ERROR; GENERATION SYSTEMS; CONTROL STRATEGY; CONVERTERS; DISTORTION; HARMONICS; FEEDBACK;
D O I
10.6113/JPE.2016.16.1.297
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
080906 [电磁信息功能材料与结构]; 082806 [农业信息与电气工程];
摘要
Grid-connected inverters (GCIs) with an LCL output filter have the ability of attenuating high-frequency (HF) switching ripples. However, by using only grid-current control, the system is prone to resonances if it is not properly damped, and the current distortion is amplified significantly under highly distorted grid conditions. This paper proposes a synchronous reference frame equivalent proportional-integral (SRF-EPI) controller in the alpha beta stationary frame using the parallel virtual resistance-based active damping (PVR-AD) strategy for grid-interfaced distributed generation (DG) systems to suppress LCL resonance. Although both a proportional-resonant (PR) controller in the alpha beta stationary frame and a PI controller in the dq synchronous frame achieve zero steady-state error, the amplitude- and phase-frequency characteristics differ greatly from each other except for the reference tracking at the fundamental frequency. Therefore, an accurate SRF-EPI controller in the alpha beta stationary frame is established to achieve precise tracking accuracy. Moreover, the robustness, the harmonic rejection capability, and the influence of the control delay are investigated by the Nyquist stability criterion when the PVR-based AD method is adopted. Furthermore, grid voltage feed-forward and multiple PR controllers are integrated into the current loop to mitigate the current distortion introduced by the grid background distortion. In addition, the parameters design guidelines are presented to show the effectiveness of the proposed strategy Finally, simulation and experimental results are provided to validate the feasibility of the proposed control approach.
引用
收藏
页码:297 / 309
页数:13
相关论文
共 33 条
[1]
Suppression of line voltage related distortion in current controlled grid connected inverters [J].
Abeyasekera, T ;
Johnson, CM ;
Atkinson, DJ ;
Armstrong, M .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2005, 20 (06) :1393-1401
[2]
Control of Grid-Connected Inverters Using Adaptive Repetitive and Proportional Resonant Schemes [J].
Abusara, Mohammad A. ;
Sharkh, Suleiman M. ;
Zanchetta, Pericle .
JOURNAL OF POWER ELECTRONICS, 2015, 15 (02) :518-529
[3]
Step-by-Step Controller Design for LCL-Type Grid-Connected Inverter with Capacitor-Current-Feedback Active-Damping [J].
Bao, Chenlei ;
Ruan, Xinbo ;
Wang, Xuehua ;
Li, Weiwei ;
Pan, Donghua ;
Weng, Kailei .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (03) :1239-1253
[4]
Simplified Feedback Linearization Control of Three-Phase Photovoltaic Inverter With an LCL Filter [J].
Bao, Xianwen ;
Zhuo, Fang ;
Tian, Yuan ;
Tan, Peixuan .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (06) :2739-2752
[5]
Beres R., 2014, IEEE POW EL C MAY, P18
[6]
Overview of control and grid synchronization for distributed power generation systems [J].
Blaabjerg, Frede ;
Teodorescu, Remus ;
Liserre, Marco ;
Timbus, Adrian V. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) :1398-1409
[7]
Filter-Based Active Damping of Voltage Source Converters With LCL Filter [J].
Dannehl, Joerg ;
Liserre, Marco ;
Fuchs, Friedrich Wilhelm .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (08) :3623-3633
[8]
Investigation of Active Damping Approaches for PI-Based Current Control of Grid-Connected Pulse Width Modulation Converters With LCL Filters [J].
Dannehl, Joerg ;
Fuchs, Friedrich Wilhelm ;
Hansen, Steffan ;
Thogersen, Paul Bach .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2010, 46 (04) :1509-1517
[9]
Dick Christian P., 2007, 2007 European Conference on Power Electronics and Applications, P1, DOI 10.1109/EPE.2007.4417362
[10]
Two Degrees of Freedom Active Damping Technique for LCL Filter-Based Grid Connected PV Systems [J].
Hanif, Moin ;
Khadkikar, Vinod ;
Xiao, Weidong ;
Kirtley, James L., Jr. .