Percutaneous implantation of a valve in the descending aorta in lambs

被引:49
作者
Boudjemline, Y
Bonhoeffer, P
机构
[1] Great Ormond St Hosp Children NHS Trust, Cardiothorac Unit, London WC1N 3JH, England
[2] Hop Necker Enfants Malad, Serv Cardiol Pediat, Paris, France
关键词
stems; catheterization; prosthesis; valves; aortic valve disease;
D O I
10.1053/euhj.2001.3076
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims We assessed the feasibility of percutaneous implantation of a valve in the descending aorta and its function in systemic pressures. Methods and Results A biological valve harvested from a bovine jugular vein was sutured into a stent. After the creation of aortic insufficiency, the valved stent was percutaneously implanted into eight lambs divided into two groups depending on the severity of the insufficiency created. Haemodynamic and angiographic evaluations were carried out. Anatomical evaluation was finally performed. Aortic insufficiency was created: four lambs had mild insufficiency and four massive insufficiency. A valve was successfully implanted in all and were functioning perfectly in the early follow-up. Despite this competence, animals with massive insufficiency died within 24 h following implantation. None of the animals with mild insufficiency died. The valve was functioning perfectly in the first 2 months following the implantation, but became incompetent after spontaneous healing of the wound of the aortic valve. Conclusion Percutaneously implanted valves in the descending aorta of lambs with aortic insufficiency function well in the early follow-up. This technique might become an interesting alternative to the standard approach in patients in whom perioperative risk is high. (C) 2002 The European Society of Cardiology. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1045 / 1049
页数:5
相关论文
共 12 条
[1]  
ANTONATOS PG, 1991, CARDIOVASC RES, V12, P995
[2]   CORONARY BLOOD-FLOW RESERVE IN ACUTE AORTIC REGURGITATION [J].
ARDEHALI, A ;
SEGAL, J ;
CHEITLIN, MD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (06) :1387-1392
[3]   Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction [J].
Bonhoeffer, P ;
Boudjemline, Y ;
Saliba, Z ;
Merckx, J ;
Aggoun, Y ;
Bonnet, D ;
Acar, P ;
Le Bidois, J ;
Sidi, D ;
Kachaner, J .
LANCET, 2000, 356 (9239) :1403-1405
[4]   Transcatheter implantation of a bovine valve in pulmonary position - A lamb study [J].
Bonhoeffer, P ;
Boudjemline, Y ;
Saliba, Z ;
Hausse, AO ;
Aggoun, Y ;
Bonnet, D ;
Sidi, D ;
Kachaner, J .
CIRCULATION, 2000, 102 (07) :813-816
[5]  
FELDMAN RL, 1983, J AM COLL CARDIOL, V1, P1281, DOI 10.1016/S0735-1097(83)80141-7
[6]   AORTIC-VALVE REPLACEMENT - DETERMINANTS OF OPERATIVE MORTALITY [J].
HE, GW ;
ACUFF, TE ;
RYAN, WH ;
DOUTHIT, MB ;
BOWMAN, RT ;
HE, YH ;
MACK, MJ .
ANNALS OF THORACIC SURGERY, 1994, 57 (05) :1140-1146
[7]   CORONARY FLOW RESERVE [J].
HOFFMAN, JIE .
CURRENT OPINION IN CARDIOLOGY, 1988, 3 (06) :874-880
[8]  
HUFNAGEL CA, 1954, SURGERY, V35, P673
[9]  
HUFNAGEL CA, 1976, J THORAC CARDIOV SUR, V72, P900
[10]   INFLUENCES OF LOCALIZED AORTIC-VALVE DAMAGE ON CORONARY-ARTERY BLOOD-FLOW IN ACUTE AORTIC REGURGITATION - AN EXPERIMENTAL-STUDY [J].
NAKAO, S ;
NAGATOMO, T ;
KIYONAGA, K ;
KASHIMA, T ;
TANAKA, H .
CIRCULATION, 1987, 76 (01) :201-207