Quality control tests for the CMS Barrel RPCs

被引:4
作者
Abbrescia, M.
Colaleo, A.
Guida, R.
Iaselli, G.
Loddo, F.
Maggi, M.
Marangelli, B.
Natali, S.
Nuzzo, S.
Pugliese, G.
Ranieri, A.
Romano, F.
Trentadue, R.
Cavallo, N.
Fabozzi, F.
Paolucci, P.
Piccolo, D.
Polese, G.
Sciacca, C.
Belli, G.
Necchi, M.
Ratti, S. P.
Riccardi, C.
Torre, P.
Vitulo, P.
Anguelov, T.
Genchev, V.
Panev, B.
Piperov, S.
Sultanov, G.
Vankov, P.
Dimitrov, A.
Litov, L.
Pavlov, B.
Petkov, P.
机构
[1] Dipartimento Interateneo Fis, I-70126 Bari, Italy
[2] Ist Nazl Fis Nucl, I-70126 Bari, Italy
[3] Univ Basilicata, Naples, Italy
[4] Ist Nazl Fis Nucl, I-80125 Naples, Italy
[5] Dipartimento Fis, I-80125 Naples, Italy
[6] Univ Pavia, Dipartimento Fis Nucl & Teor, I-27100 Pavia, Italy
[7] Bulgarian Acad Sci, INRNE, Soa, Bulgaria
[8] Univ Soa St, Kliment Ohridski, Bulgaria
关键词
D O I
10.1016/j.nuclphysbps.2006.08.051
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
An RPC based system will be employed for the CMS muon first level trigger. Severe quality controls and certification have been established all along the entire production chain. Procedures are briefly described and results for the acceptance percentage axe given for the second part of the single gaps and double gaps production. Summary results axe also reported for the full sets of tested chambers.
引用
收藏
页码:73 / 77
页数:5
相关论文
共 9 条
[1]   Production and quality control of the Barrel RPC chambers of the CMS experiment [J].
Abbrescia, M ;
Cavallo, E ;
Colaleo, A ;
Iaselli, G ;
Loddo, F ;
Maggi, M ;
Marangelli, B ;
Natali, S ;
Nuzzo, S ;
Pulgliese, G ;
Ranieri, A ;
Romano, F ;
Trentadue, R ;
Cavallo, N ;
Comunale, G ;
Fabozzi, F ;
Paolucci, P ;
Piccolo, D ;
Sciacca, C ;
Belli, G ;
De Vecchi, C ;
Guida, R ;
Ratti, SP ;
Riccardi, G ;
Torre, P ;
Vitulo, P ;
Young, B ;
Tao, LH ;
Si-Jin, Q ;
Yan-Lin, Y ;
Jun, Y ;
Anguelov, T ;
Guenchev, V ;
Panev, B ;
Piperov, S ;
Sultanov, G ;
Vankov, P ;
Dimitrov, A ;
Glushkov, I ;
Litov, L ;
Nasteva, I ;
Pavlov, B ;
Petkov, P .
NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2006, 150 :290-294
[2]   Cosmic ray tests of double-gap resistive plate chambers for the CMS experiment [J].
Abbrescia, M ;
Cavallo, E ;
Colaleo, A ;
Iaselli, G ;
Loddo, F ;
Maggi, M ;
Marangelli, B ;
Natali, S ;
Nuzzo, S ;
Pugliese, G ;
Ranieri, A ;
Romano, F ;
Trentadue, R ;
Cavallo, N ;
Comunale, G ;
Paolucci, P ;
Piccolo, D ;
Sciacca, C ;
Belli, G ;
De Vecchi, C ;
Guida, R ;
Ratti, SP ;
Riccardi, C ;
Torre, P ;
Vitulo, P ;
Ban, Y ;
Cai, J ;
Liu, H ;
Qian, S ;
Wang, Q ;
Ye, Y ;
Ying, J ;
Dimitrov, A ;
Glushkov, I ;
Litov, L ;
Nasteva, I ;
Pavlov, B ;
Petkov, P ;
Anguelov, T ;
Genchev, V ;
Iaydjiev, P ;
Panev, B ;
Stoykova, S ;
Sultanov, G ;
Trayanov, R ;
Vankovf, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 550 (1-2) :116-126
[3]   RESISTIVE PLATE CHAMBERS PERFORMANCES AT COSMIC-RAYS FLUXES [J].
ABBRESCIA, M ;
CARDARELLI, R ;
IASELLI, G ;
NATALI, S ;
NUZZO, S ;
RANIERI, A ;
ROMANO, F ;
SANTONICO, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 359 (03) :603-609
[4]   Recent results and developments on double-gap RPCs for CMS [J].
Abbrescia, M ;
Colaleo, A ;
Iaselli, G ;
Loddo, F ;
Maggi, M ;
Marangelli, B ;
Natali, S ;
Nuzzo, S ;
Pugliese, G ;
Ranieri, A ;
Romano, F ;
Gianini, G ;
Ratti, SP ;
Vitulo, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3) :43-45
[5]   The simulation of resistive plate chambers in avalanche mode: charge spectra and efficiency [J].
Abbrescia, M ;
Colaleo, A ;
Iaselli, G ;
Loddo, F ;
Maggi, M ;
Marangelli, B ;
Natali, S ;
Nuzzo, S ;
Pugliese, G ;
Ranieri, A ;
Romano, F ;
Altieri, S ;
Bruno, G ;
Gianini, G ;
Ratti, SP ;
Viola, L ;
Vitulo, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 431 (03) :413-427
[6]  
Aielli G, 2006, NUCL INSTRUM METH A, V562, P92, DOI [10.1016/j.nima.2006.02.136, 10.1016/j.nima.2006.02.0136]
[7]   THE L3 FORWARD-BACKWARD MUON RPC TRIGGER SYSTEM [J].
ALOISIO, A ;
ALVIGGI, MG ;
CARLINO, G ;
CAVALLO, N ;
DEASMUNDIS, R ;
INNOCENTE, V ;
LANZANO, S ;
LISTA, L ;
PAOLUCCI, P ;
PICCOLO, D ;
PATRICELLI, S ;
SCIACCA, C ;
SOULIMOV, V .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 360 (1-2) :340-344
[8]  
*CMS COLL, 1994, CERNLHCC9438 CMS COL
[9]   The RPC-based IFR system at BaBar experiment: preliminary results [J].
Piccolo, D ;
Palano, A ;
Bagnasco, S ;
Buzzo, A ;
Contri, R ;
Crosetti, G ;
Lo Vetere, M ;
Macri, M ;
Monge, R ;
Passaggio, S ;
Patrignani, C ;
Robutti, E ;
Santroni, A ;
Anulli, F ;
Baldini, R ;
Calcaterra, A ;
De Sangro, R ;
Falciai, D ;
Finocchiaro, G ;
Patteri, P ;
Peruzzi, I ;
Piccolo, M ;
Yu, Z ;
Zallo, A ;
Cavallo, N ;
De Nardo, G ;
Fabozzi, F ;
Gatto, C ;
Lista, L ;
Paolucci, P ;
Sciacca, C ;
Bionta, R ;
Wright, D ;
Band, H ;
Johnson, J .