Biomechanics of the Gazi type pelvis external skeletal fixator

被引:2
作者
Korkusuz, F
Kaymak, O
Citipitioglu, E
Akkas, N
机构
[1] GAZI UNIV,SCH MED,DEPT ORTHOPAED SURG & TRAUMATOL,ANKARA,TURKEY
[2] MIDDLE E TECH UNIV,DEPT CIVIL ENGN,TR-06531 ANKARA,TURKEY
[3] MIDDLE E TECH UNIV,DEPT ENGN SCI,TR-06531 ANKARA,TURKEY
关键词
biomechanics; external fixator; pelvis; fracture;
D O I
10.1243/0954411971534520
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
External skeletal fixation is an alternative method of treatment to conventional therapy and open surgical procedures in pelvis fractures. The appropriate type of frame and the configuration of the connecting bars of these fixators are under investigation. In the Gazi type pelvis external fixator (GPEF) which has been developed, a 70 degrees angulation is applied to the connecting bars of the anterior quadrangular frame. This configuration, which is expected to improve the stability of the posterior column of the pelvis, was evaluated biomechanically on a phantom with various types of pelvic fractures and separations. The results suggest that the GPEF effectively controls anterior column pelvis fractures such as unilateral pubic ramus fractures, unilateral ischium pubis rami fractures and symphysis pubis separations under vertical loads. The fixator is partially capable of stabilizing the posterior column; however, loads above 700 N cause separation at the fracture site. Further studies and clinical trials are essential to determine the GPEF's effectiveness in reducing blood loss and in providing stability at the posterior column.
引用
收藏
页码:401 / 409
页数:9
相关论文
共 18 条
[1]
BUHREN V, 1990, ZBL CHIR, V115, P581
[2]
DABEZIES EJ, 1989, CLIN ORTHOPAEDICS, V246, P165
[3]
DEVELOPMENT AND VALIDATION OF A 3-DIMENSIONAL FINITE-ELEMENT MODEL OF THE PELVIC BONE [J].
DALSTRA, M ;
HUISKES, R ;
VANERNING, L .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1995, 117 (03) :272-278
[4]
GOLDSTEIN A, 1986, J TRAUMA, V26, P325
[5]
FIXATION OF PELVIC FRACTURES AND DISLOCATIONS - EXPERIMENTAL-STUDY ON LOADING OF PELVIC FRACTURES AND SACRO-ILIAC DISLOCATIONS AFTER EXTERNAL COMPRESSION FIXATION [J].
GUNTERBERG, B ;
GOLDIE, I ;
SLATIS, P .
ACTA ORTHOPAEDICA SCANDINAVICA, 1978, 49 (03) :278-286
[6]
KAYMAK O, 1985, 8 C INT CHIR ORTH TR
[7]
KELAM JF, 1989, CLIN ORTHOPAEDICS, V241, P66
[8]
KORKUSUZ F, 1994, TURKISH J BONE JT SU, V1, P94
[9]
KUNAK F, 1985, THESIS GAZI U ANKARA
[10]
IMPROVED OUTCOME WITH EARLY FIXATION OF SKELETALLY UNSTABLE PELVIC FRACTURES [J].
LATENSER, BA ;
GENTILELLO, LM ;
TARVER, AA ;
THALGOTT, JS ;
BATDORF, JW .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1991, 31 (01) :28-31