Dew water collector for potable water in Ajaccio (Corsica Island, France)

被引:132
作者
Muselli, M
Beysens, D
Marcillat, J
Milimouk, I
Nilsson, T
Louche, A
机构
[1] Int Org Dew Utilizat, F-33600 Pessac, France
[2] Univ Corse, CNRS, UMR 6134, F-20000 Ajaccio, France
[3] CEA, Equipe Supercrit Environm Mat & Espace, Grenoble, France
[4] IMT, Lab Modelisat & Simulat Numer Mecan, F-13451 Marseille, France
[5] CNRS, ESEME, ICMCB, Equipe Supercrit Environm Mat & Espace, F-33608 Pessac, France
关键词
water production; chemical analysis; hydrometeorology; atmospheric deposition;
D O I
10.1016/S0169-8095(02)00100-X
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
We report on the development of an inexpensive radiative condenser for collecting atmospheric vapor. Based on the experience gained rising a small working model in Grenoble (France), a prototype of 10x3 m(2) was established in Ajaccio (Corsica, France). The condensing surface is a rectangular foil made of TiO2 and BaSO4 microspheres embedded in polyethylene and has an angle of 30degrees with respect to horizontal. The hollow part of the device, thermally isolated, faces the direction of the dominant nocturnal wind. Dew measurements were correlated with meteorological data and compared to dew condensed on a horizontal polymethylmethacrylate (PMMA, Plexiglas) reference plate. The plate served as a reference standard unit and was located nearby. Between July 22, 2000 and November 11, 2001 (478 days), there were 145 dew days for the reference plate (30%), but 214 dew days for the condenser (45%). This yield corresponds to 767 1 (3.6 1, on average, per dew day). The maximum yield in the period was 11.4 l/day. Dew mass can be fitted to a simple model that predicts dew production from simple meteorological data (temperature, humidity, wind velocity, cloud cover). Chemical analyses of the water collected from the plate were performed from October 16, 1999 to July 16, 2000 and from the condenser, from July 17, 2000 to March 17, 2001. The following parameters were investigated: suspended solids, pH, concentration of SO42-, Cl-, K+, Ca2+ ions. Only Cl- and SO42- ions were sometimes found significant. Wind direction analyses revealed that Cl- is due to the sea spray and SO42- to the combustion of fuel by an electrical plant located in the Ajaccio Gulf. Except for a weak acidity (average pH approximate to 6) and high concentration of suspended solids, dew water fits the requirements for potable water in France with reference to the above ions. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:297 / 312
页数:16
相关论文
共 14 条
[1]   Use of condensed water vapour from the atmosphere for irrigation in Bahrain [J].
Alnaser, WE ;
Barakat, A .
APPLIED ENERGY, 2000, 65 (1-4) :3-18
[2]   THE FORMATION OF DEW [J].
BEYSENS, D .
ATMOSPHERIC RESEARCH, 1995, 39 (1-3) :215-237
[3]  
BEYSENS D, 2001, J HYDROL
[4]  
BEYSENS DA, 1998, P 1 INT C FOG FOG CO, P269
[5]  
Chaptal L, 1932, NATURE, V60, P449
[6]  
JUKOV NN, 1931, DREVNIH GYDROTEHNICK, V1, P68
[7]  
Jumikis A., 1965, SOIL SCI VOLUME, V100, P83, DOI DOI 10.1097/00010694-196508000-00002
[8]  
KNAPEN MA, 1929, B JAN FEB 1929 IMPR
[9]   DEW [J].
MONTEITH, JL .
QUARTERLY JOURNAL OF THE ROYAL METEOROLOGICAL SOCIETY, 1957, 83 (357) :322-341
[10]   Water recovery from dew [J].
Nikolayev, VS ;
Beysens, D ;
Gioda, A ;
Milimouk, I ;
Katiushin, E ;
Morel, JP .
JOURNAL OF HYDROLOGY, 1996, 182 (1-4) :19-35