Direct potentiometric information on total ionic concentrations

被引:28
作者
Ceresa, A
Pretsch, E [1 ]
Bakker, E
机构
[1] Auburn Univ, Dept Chem, Auburn, AL 36849 USA
[2] ETH Zurich, Swiss Fed Inst Technol, Dept Organ Chem, CH-8092 Zurich, Switzerland
关键词
D O I
10.1021/ac991092h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Polymeric membrane ion-selective electrodes exhibit an apparently super-Nernstian response at low sample activities if inner solutions are used that induce strong zero-current fluxes of primary ions toward the inner compartment. This is due to the limited ion fluxes in the aqueous boundary layer near the membrane. In the presence of labile complexes, the effective nux rate is increased and the emf depends on the total concentration of the ions. The concept is illustrated experimentally with calcium-selective electrodes based on the ionophore N,N-dicyclohexyl-N',N' -dioctadecyl-3-oxapentanediamide (ETH 5234) that-either respond to total or free ion concentrations. Samples can be distinguished that contain varying levels of total calcium but are all buffered with EDTA to the same free calcium concentration of 5 x 10(-8) M.
引用
收藏
页码:2050 / 2054
页数:5
相关论文
共 28 条
[1]  
[Anonymous], 1972, INT SERIES MONOGRAPH, DOI DOI 10.1016/C2013-0-02416-4
[2]   Selectivity of potentiometric ion sensors [J].
Bakker, E ;
Pretsch, E ;
Bühlmann, P .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1127-1133
[3]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[4]   Origin of anion response of solvent polymeric membrane based silver ion-selective electrodes [J].
Bakker, E .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 35 (1-3) :20-25
[5]   STUDY OF BEHAVIOR OF SOLID-STATE MEMBRANE ELECTRODES .3. MODEL FOR RESPONSE-TIME [J].
BUFFLE, J ;
PARTHASARATHY, N .
ANALYTICA CHIMICA ACTA, 1977, 93 (01) :111-120
[6]   REFERENCE ELECTRODE WITH FREE-FLOWING FREE-DIFFUSION LIQUID JUNCTION [J].
DOHNER, RE ;
WEGMANN, D ;
MORF, WE ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1986, 58 (12) :2585-2589
[7]   RESPONSE MECHANISM OF POLYMER MEMBRANE-BASED POTENTIOMETRIC POLYION SENSORS [J].
FU, B ;
BAKKER, E ;
YUN, JH ;
YANG, VC ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1994, 66 (14) :2250-2259
[8]   Voltammetric and amperometric transduction for solvent polymeric membrane ion sensors [J].
Jadhav, S ;
Bakker, E .
ANALYTICAL CHEMISTRY, 1999, 71 (17) :3657-3664
[9]   RESPONSE-TIME STUDIES FOR PRECIPITATE-BASED ION-SELECTIVE ELECTRODES IN THE RANGE OF THE LOWER DETECTION LIMIT [J].
LINDNER, E ;
TOTH, K ;
PUNGOR, E .
ANALYTICAL CHEMISTRY, 1982, 54 (01) :72-76
[10]  
Lindner E, 1999, ELECTROANAL, V11, P695, DOI 10.1002/(SICI)1521-4109(199907)11:10/11<695::AID-ELAN695>3.0.CO