Voxel similarity measures for 3-D serial MR brain image registration

被引:220
作者
Holden, M [1 ]
Hill, DLG
Denton, ERE
Jarosz, JM
Cox, TCS
Rohlfing, T
Goodey, J
Hawkes, DJ
机构
[1] Kings Coll London, Guys Kings & St Thomas Sch Med, London SE1 9RT, England
[2] Kings Coll Hosp London, Dept Radiol, London SE5 9RS, England
[3] Kings Coll Hosp London, Neuroimaging Dept, London SE5 9RS, England
[4] UCL, Inst Neurol, London WC1N 3BG, England
[5] Humboldt Univ, Fac Med, Charite, Campus Virchow Hosp,Dept Radiol, D-13353 Berlin, Germany
关键词
consistency of transformation estimates; evaluation with clinical data; serial MR registration; voxel-based similarity measures;
D O I
10.1109/42.836369
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We have evaluated eight different similarity measures used for rigid body registration of serial magnetic resonance (MR) brain scans. To assess their accuracy we used 33 clinical three-dimensional (3-D) serial MR images, with deformable extradural tissue excluded by manual segmentation and simulated 3-D MR images with added intensity distortion. For each measure we determined the consistency of registration transformations for both sets of segmented and unsegmented data. We have shown that of the eight measures tested, the ones based on joint entropy produced the best consistency. In particular, these measures seemed to be least sensitive to the presence of extradural tissue. For these data the difference in accuracy of these joint entropy measures, with or without brain segmentation, was within the threshold of visually detectable change in the difference images.
引用
收藏
页码:94 / 102
页数:9
相关论文
共 34 条
  • [1] [Anonymous], 1994, P VBC
  • [2] Bland M, 1995, INTRO MED STAT
  • [3] Bradley WG, 1997, ADV MR IMAGING TECHN
  • [4] A SURVEY OF IMAGE REGISTRATION TECHNIQUES
    BROWN, LG
    [J]. COMPUTING SURVEYS, 1992, 24 (04) : 325 - 376
  • [5] Buzug TM, 1996, LECT NOTES COMPUT SC, V1131, P235, DOI 10.1007/BFb0046959
  • [6] BUZUG TM, 1997, LECT NOTES COMPUTER, V1205, P119
  • [7] COLLIGNON A, 1995, COMP IMAG VIS, V3, P263
  • [8] Design and construction of a realistic digital brain phantom
    Collins, DL
    Zijdenbos, AP
    Kollokian, V
    Sled, JG
    Kabani, NJ
    Holmes, CJ
    Evans, AC
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (03) : 463 - 468
  • [9] The identification of cerebral volume changes in treated growth hormone-deficient adults using serial 3D MR image processing
    Denton, ERE
    Holden, M
    Christ, E
    Jarosz, JM
    Russell-Jones, D
    Goodey, J
    Cox, TCS
    Hill, DLG
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (01) : 139 - 145
  • [10] The boundary shift integral: An accurate and robust measure of cerebral volume changes from registered repeat MRI
    Freeborough, PA
    Fox, NC
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (05) : 623 - 629