Design and performance of the solar-powered floor heating system in a green building

被引:37
作者
Zhai, X. Q. [1 ]
Yang, J. R. [2 ]
Wang, R. Z. [1 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai 200240, Peoples R China
[2] Shanghai Res Inst Bldg Sci, Shanghai 200031, Peoples R China
关键词
Solar energy; Floor heating system; Experimental investigation; Performance analysis; SIMULATION; ENERGY; FIELD; MODEL;
D O I
10.1016/j.renene.2008.11.027
中图分类号
X [环境科学、安全科学];
学科分类号
083001 [环境科学];
摘要
In the green building of Shanghai Research Institute of Building Science, the evacuated tubular solar collectors with a total area of 150 m(2) were installed to provide heating for the covered area of 460 m(2). The floor heating coil pipes were made of high-quality pure copper with the dimension of Phi 12 x 0.7 mm. Under typical weather condition of Shanghai, the average heating capacity was 25.04 kW during the working hours from 9:00 to 17:00, which was sufficient to keep indoor thermal environment. The average electric COP of the floor heating system was 19.76 during the system operation. Compared with the widely used air-source heat pump heating systems with the electric COP of 3.5 in Shanghai, the solar-powered floor heating system shows great potential in energy conservation in winter. With respect to the whole heating period, the solar fraction was 56%. According to the performance analysis of the system with ambient parameters, it was observed that the system performance could be greatly enhanced with the increase of daily solar insolation. However, the system performance varied slightly with average ambient temperature. Compared with average ambient temperature, daily solar insolation had a more distinct influence on the performance of the solar-powered floor heating system. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1700 / 1708
页数:9
相关论文
共 15 条
[1]
Modeling and simulation of solar pond floor heating system [J].
Alkhalaileh, MT ;
Atieh, KA ;
Nasser, NG ;
Jubran, BA .
RENEWABLE ENERGY, 1999, 18 (01) :1-14
[2]
Numerical simulation and performance assessment of a low capacity solar assisted absorption heat pump coupled with a sub-floor system [J].
Argiriou, AA ;
Balaras, CA ;
Kontoylannidis, S ;
Michel, E .
SOLAR ENERGY, 2005, 79 (03) :290-301
[3]
The effect of solar radiation on dynamic thermal performance of floor heating systems [J].
Athienitis, AK ;
Chen, Y .
SOLAR ENERGY, 2000, 69 (03) :229-237
[4]
Comparative study for under-floor heating using solar collectors or solar ponds [J].
Badran, AA ;
Hamdan, MA .
APPLIED ENERGY, 2004, 77 (01) :107-117
[5]
CHEN G, 2005, THESIS SHANGHAI JIAO
[6]
Dynamics of three-dimensional temperature field in electrical system of floor heating [J].
Golebiowski, J ;
Kwieckowski, S .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2002, 45 (12) :2611-2622
[7]
Field performance of a Japanese low energy home relying on renewable energy [J].
Hamada, Y ;
Nakamura, M ;
Ochifuji, K ;
Nagano, K ;
Yokoyama, S .
ENERGY AND BUILDINGS, 2001, 33 (08) :805-814
[8]
SIMULATION OF THE DYNAMIC BEHAVIOR OF A HYDRONIC FLOOR HEATING-SYSTEM [J].
HO, SY ;
HAYES, RE ;
WOOD, RK .
HEAT RECOVERY SYSTEMS & CHP, 1995, 15 (06) :505-519
[9]
Energy consumption and thermal comfort in dwelling-cells: A zonal-model approach [J].
Inard, C ;
Meslem, A ;
Depecker, P .
BUILDING AND ENVIRONMENT, 1998, 33 (05) :279-291
[10]
Performance of a multi-functional direct-expansion solar assisted heat pump system [J].
Kuang, Y. H. ;
Wang, R. Z. .
SOLAR ENERGY, 2006, 80 (07) :795-803