Reproducibility of heart rate and blood pressure variability in patients with chronic obstructive pulmonary disease

被引:15
作者
Bartels, MN
Jelic, S
Gonzalez, JM
Kim, W
De Meersman, RE
机构
[1] Columbia Univ, Coll Phys & Surg, Dept Rehabil Med, New York, NY 10034 USA
[2] Columbia Univ, Coll Phys & Surg, Div Pulm Allergy & Crit Care Med, New York, NY 10034 USA
关键词
COPD; time frequency analysis; heart rate variability; blood pressure variability;
D O I
10.1007/s10286-004-0183-1
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Wide variations in respiratory rate and hypoxic stimulation of chemoreceptors may produce unreliable autonomic results in patients with COPD. We studied the reproducibility of two consecutive measurements of heart rate variability (HRV) and blood pressure variability (BPV) by time frequency analysis in patients with COPD while controlling respiratory rate and oxygen hemoglobin saturation (SaO(2)). Reproducibility was assessed by paired t-tests and correlation analyses between repeated measures. Correlation analyses of the log transformed low (U) and high frequency (HF) HRV were (x) over bar 11.5+/-1.1 in measurement A and (x) over bar 11.5+/-1.0 in measurement B (r=0.89, p<0.0001), and <(x)over bar> 10.5+/-1.1 in measurement A and (x) over bar 10.6+/-1.1 in measurement B (r=0.89, p<0.0001) respectively. The log transformed LF and HF BPV were <(c)over bar> 4.9+/-1.3 in measurement A and (x) over bar 5.3+/-0.9 in measurement B (r=0.70, p<0.0002), and <(x)over bar> 6.4+/-1.3 in measurement A and 6.6+/-1.2 in measurement B (R=0.71 p<0.0001) respectively. In conclusion, time frequency analysis of HRV and BPV is reproducible and reliable in patients with COPD while controlling their respiratory rate and oxygen hemoglobin saturation. Reproducibility of these measurements may allow for a non-invasive evaluation of autonomic tone in response to treatments in COPD patients.
引用
收藏
页码:194 / 196
页数:3
相关论文
共 15 条
[1]   POWER SPECTRUM ANALYSIS OF HEART-RATE FLUCTUATION - A QUANTITATIVE PROBE OF BEAT-TO-BEAT CARDIOVASCULAR CONTROL [J].
AKSELROD, S ;
GORDON, D ;
UBEL, FA ;
SHANNON, DC ;
BARGER, AC ;
COHEN, RJ .
SCIENCE, 1981, 213 (4504) :220-222
[2]   BEAT TO BEAT VARIABILITY IN CARDIOVASCULAR VARIABLES - NOISE OR MUSIC [J].
APPEL, ML ;
BERGER, RD ;
SAUL, JP ;
SMITH, JM ;
COHEN, RJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (05) :1139-1148
[3]   STABILITY OVER TIME OF HEART PERIOD VARIABILITY IN PATIENTS WITH PREVIOUS MYOCARDIAL-INFARCTION AND VENTRICULAR ARRHYTHMIAS [J].
BIGGER, JT ;
FLEISS, JL ;
ROLNITZKY, LM ;
STEINMAN, RC .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (08) :718-723
[4]  
Camm AJ, 1996, CIRCULATION, V93, P1043
[5]   TEMPORAL CONSISTENCY OF INDIVIDUAL-DIFFERENCES IN CARDIAC RESPONSE TO A VIDEO GAME [J].
CARROLL, D ;
TURNER, JR ;
LEE, HJ ;
STEPHENSON, J .
BIOLOGICAL PSYCHOLOGY, 1984, 19 (02) :81-93
[6]  
DEMEERSMAN R, 1995, AM J PHYSIOL, V270, pH1437
[7]   RELIABLE MEASURES OF BEHAVIORALLY-EVOKED CARDIOVASCULAR REACTIVITY FROM A PC-BASED TEST BATTERY - RESULTS FROM STUDENT AND COMMUNITY SAMPLES [J].
KAMARCK, TW ;
JENNINGS, JR ;
DEBSKI, TT ;
GLICKMANWEISS, E ;
JOHNSON, PS ;
EDDY, MJ ;
MANUCK, SB .
PSYCHOPHYSIOLOGY, 1992, 29 (01) :17-28
[8]  
KITNEY RI, 1995, COMPUTER ANAL CARDIO, P41
[9]   STABILITY OVER TIME OF VARIABLES MEASURING HEART-RATE-VARIABILITY IN NORMAL SUBJECTS [J].
KLEIGER, RE ;
BIGGER, JT ;
BOSNER, MS ;
CHUNG, MK ;
COOK, JR ;
ROLNITZKY, LM ;
STEINMAN, R ;
FLEISS, JL .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (06) :626-630
[10]   LOW-FREQUENCY OSCILLATIONS IN ARTERIAL-PRESSURE AND HEART-RATE - A SIMPLE COMPUTER-MODEL [J].
MADWED, JB ;
ALBRECHT, P ;
MARK, RG ;
COHEN, RJ .
AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 256 (06) :H1573-H1579