Development of a computerized method for identifying the posteroanterior and lateral views of chest radiographs by use of a template matching technique

被引:25
作者
Arimura, H
Katsuragawa, S
Li, G
Ishida, T
Doi, K
机构
[1] Univ Chicago, Dept Radiol, Kurt Rossmann Labs Radiol Image Res, Chicago, IL 60637 USA
[2] Hiroshima Int Univ, Fac Hlth Sci, Dept Clin Radiol, Hiroshima 7240695, Japan
[3] Nippon Bunri Univ, NBU Gen Res Ctr, Oita 8700397, Japan
关键词
PACS; computer-aided diagnosis; image analysis; chest radiographs; template matching technique;
D O I
10.1118/1.1487426
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
In picture archiving and communications systems (PACS) or digital archiving systems, the information on the posteroanterior (PA) and lateral views for chest radiographs is often not recorded or is recorded incorrectly. However. it is necessary to identify the PA or lateral view correctly and automatically for quantitative analysis of chest images for computer-aided diagnosis. Our purpose in this study was to develop a computerized method for correctly identifying either PA or lateral views of chest radiographs. Our approach is to examine the similarity of a chest image with templates that represent the average chest images of the PA or lateral view for various types of patients. By use of a template matching technique with nine template images for patients of different size in two steps, correlation values were obtained for determining whether a chest image is either a PA or a lateral view. The templates for PA and lateral views were prepared from 447 PA and 200 lateral chest images. For a validation test, this scheme was applied to 1,000 test images consisting of 500 PA and 500 lateral chest radiographs, which are different from training cases. In the first step, 924 (92.4%) of the cases were correctly identified by comparison of the correlation values obtained with the three templates for medium-size patients. In the second step, the correlation values with the six templates for small and large patients were compared. and all of the remaining unidentifiable cases were identified correctly. (C) 2002 American Association of Physicists in Medicine.
引用
收藏
页码:1556 / 1561
页数:6
相关论文
共 14 条
[1]
Automated lung segmentation in digitized posteroanterior chest radiographs [J].
Armato, SG ;
Giger, ML ;
MacMahon, H .
ACADEMIC RADIOLOGY, 1998, 5 (04) :245-255
[2]
Automated lung segmentation in digital lateral chest radiographs [J].
Armato, SG ;
Giger, ML ;
Ashizawa, K ;
MacMahon, H .
MEDICAL PHYSICS, 1998, 25 (08) :1507-1520
[3]
Boone J M, 1992, J Digit Imaging, V5, P190
[4]
Automatic calculation of total lung capacity from automatically traced lung boundaries in postero-anterior and lateral digital chest radiographs [J].
Carrascal, FM ;
Carreira, JM ;
Souto, M ;
Tahoces, PG ;
Gomez, L ;
Vidal, JJ .
MEDICAL PHYSICS, 1998, 25 (07) :1118-1131
[5]
A FULLY AUTOMATED ALGORITHM FOR THE SEGMENTATION OF LUNG FIELDS ON DIGITAL CHEST RADIOGRAPHIC IMAGES [J].
DURYEA, J ;
BOONE, JM .
MEDICAL PHYSICS, 1995, 22 (02) :183-191
[6]
Harreld MR, 1999, RADIOLOGY, V213P, P321
[7]
Iterative image warping technique for temporal subtraction of sequential chest radiographs to detect interval change [J].
Ishida, T ;
Katsuragawa, S ;
Nakamura, K ;
MacMahon, H ;
Doi, K .
MEDICAL PHYSICS, 1999, 26 (07) :1320-1329
[8]
Application of artificial neural networks for quantitative analysis of image data in chest radiographs for detection of interstitial lung disease [J].
Ishida, T ;
Katsuragawa, S ;
Ashizawa, K ;
MacMahon, H ;
Doi, K .
JOURNAL OF DIGITAL IMAGING, 1998, 11 (04) :182-192
[9]
DIGITAL IMAGE SUBTRACTION OF TEMPORALLY SEQUENTIAL CHEST IMAGES FOR DETECTION OF INTERVAL CHANGE [J].
KANO, A ;
DOI, K ;
MACMAHON, H ;
HASSELL, DD ;
GIGER, ML .
MEDICAL PHYSICS, 1994, 21 (03) :453-461
[10]
Quantitative analysis of geometric-pattern features of interstitial infiltrates in digital chest radiographs: Preliminary results [J].
Katsuragawa, S ;
Doi, K ;
MacMahon, H ;
MonnierCholley, L ;
Morishita, J ;
Ishida, T .
JOURNAL OF DIGITAL IMAGING, 1996, 9 (03) :137-144