HPLC separations of meropenem and selected pharmaceuticals using a polar endcapped octadecylsilane narrow bore column

被引:9
作者
Caufield, WV [1 ]
Stewart, JT [1 ]
机构
[1] Univ Georgia, Coll Pharm, Dept Pharmaceut & Biomed Sci, Athens, GA 30602 USA
关键词
column liquid chromatography; meropenem; narrow bore columns; polar endcapped phases; ranitidine;
D O I
10.1007/BF02490608
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Stability indicating high performance liquid chromatography methods have been developed for the assay of meropenem in combination with either dopamine (A), aminophylline (B), metoclopramide (C) or ranitidine (D) in intravenous fluid mixtures. Separations B, C and D were performed on a polar endcapped ODS column (150 x 2 mm) with aqueous, pH 3.0 - acetonitrile (89:11, 88:12, and 92:8) eluent and detection at 270, 290, 317 nm respectively. Meropenem was linear over the concentration ranges 126.88-507.50, 131.25-525, and 131.25-525 gmg mL(-1). Aminophylline, metoclopramide and ranitidine were linear over the concentration ranges 13-52, 37.5-150, and 25-100 mu g mL(-1). Separation A was performed on a conventional ODS column (150 x 2.1 mm) with aqueous, pH 3.0 - acetonitrile (85:15) eluent and detection at 280 nm. Meropenem and dopamine were linear in the 61.25-245 and 10-40 mu g mL(-1) ranges, respectively. Accuracy and precision for all methods were 0.20-3.30% and 0.10-1.58 %, respectively. Accelerated stability studies have been carried out on each drug by exposure to acid, base, H2O2, and heat for different time periods.
引用
收藏
页码:308 / 314
页数:7
相关论文
共 34 条
[1]   Meropenem exists in equilibrium with a carbon dioxide adduct in bicarbonate solution [J].
Almarsson, Ö ;
Kaufman, MJ ;
Stong, JD ;
Wu, YH ;
Mayr, SM ;
Petrich, MA ;
Williams, JM .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1998, 87 (05) :663-666
[2]   DETERMINATION OF MEROPENEM IN PLASMA BY HIGHPERFORMANCE LIQUID-CHROMATOGRAPHY AND A MICROBIOLOGICAL METHOD [J].
ALMESHAL, MA ;
RAMADAN, MA ;
LOTFI, KM ;
SHIBL, AM .
JOURNAL OF CLINICAL PHARMACY AND THERAPEUTICS, 1995, 20 (03) :159-163
[3]   FLUORESCENCE PROPERTIES OF METOCLOPRAMIDE AND ITS DETERMINATION IN PHARMACEUTICAL DOSAGE FORMS [J].
BAEYENS, W ;
DEMOERLOOSE, P .
ANALYST, 1978, 103 (1225) :359-367
[4]   SIMULTANEOUS HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF ADENOSINE AND DOPAMINE IN RAT STRIATAL TISSUE WITH COMBINED ULTRAVIOLET ABSORBENCY AND ELECTROCHEMICAL DETECTION [J].
BETTO, P ;
POPOLI, P ;
RICCIARELLO, G ;
CAPORALI, MG ;
ANTONINI, R .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 662 (01) :21-25
[5]  
BRUNTON LL, 1990, GOODMAN GILMANS PHAR, P926
[6]  
BRUNTON LL, 1990, GOODMAN GILMANS PHAR, P899
[7]  
BURMAN LA, 1991, J ANTIMICROB CHEMOTH, V27, P219
[8]   Rapid determination of ranitidine in human plasma by high-performance liquid chromatography [J].
Campanero, MA ;
Lopez-Ocariz, A ;
Garcia-Quetglas, E ;
Sadaba, B ;
de la Maza, A .
CHROMATOGRAPHIA, 1998, 47 (7-8) :391-395
[9]   New dual electrochemical detector for microbore liquid chromatography - Determination of dopamine and serotonin in rat striatum dialysates [J].
Cheng, FC ;
Shih, Y ;
Liang, YJ ;
Yang, LL ;
Yang, CS .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 682 (02) :195-200
[10]   COMBINATION OF TLC, GLC (OV1 AND OV17) AND HPLC (RP18) FOR A RAPID DETECTION OF DRUGS AND RELATED-COMPOUNDS [J].
DALDRUP, T ;
SUSANTO, F ;
MICHALKE, P .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1981, 308 (05) :413-427