Performance assessment of an adaptive model-based feedback controller: Comparison between atracurium, mivacurium, rocuronium and vecuronium

被引:17
作者
Kansanaho, M
Olkkola, KT
机构
[1] Department of Anaesthesia, University of Helsinki, FIN-00290 Helsinki
来源
INTERNATIONAL JOURNAL OF CLINICAL MONITORING AND COMPUTING | 1996年 / 13卷 / 04期
关键词
computers; automatic control; neuromuscular relaxants; atracurium; mivacurium; rocuronium; vecuronium;
D O I
10.1023/A:1016956507342
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The performance of an adaptive model-based controller for the administration of atracurium, mivacurium, rocuronium and vecuronium was compared in 159 adult surgical patients. The degree of neuromuscular block was set to 90% for atracurium, rocuronium and vecuronium and to 95% for mivacurium. Performance was assessed by calculating the median prediction error (bias), median absolute performance error (inaccuracy), divergence, wobble, the mean offset and the mean standard deviation from the setpoint. All indices of controller performance showed minimal deviation of the actual neuromuscular block from the setpoint. Although the controller appeared to be able to control rocuronium induced block at 90% and mivacurium induced block at 95% better than atracurium and vecuronium block at 90%, the differences in the controller performance between the four studied relaxants were small and have hardly any clinical significance. We conclude that a model-based adaptive controller is useful in the administration of atracurium, mivacurium, rocuronium or vecuronium.
引用
收藏
页码:217 / 224
页数:8
相关论文
共 21 条
[1]   CLINICAL AUTOMATIC-CONTROL OF NEUROMUSCULAR BLOCKADE [J].
ASBURY, AJ ;
LINKENS, DA .
ANAESTHESIA, 1986, 41 (03) :316-320
[2]  
Brown B. H., 1980, CLIN PHYS PHYSL MEAS, V1, P203
[3]   PHARMACOKINETIC MODEL SELECTION FOR TARGET CONTROLLED INFUSIONS OF PROPOFOL - ASSESSMENT OF 3 PARAMETER SETS [J].
COETZEE, JF ;
GLEN, JB ;
WIUM, CA ;
BOSHOFF, L .
ANESTHESIOLOGY, 1995, 82 (06) :1328-1345
[4]   INFUSION OF VECURONIUM CONTROLLED BY A CLOSED-LOOP SYSTEM [J].
DEVRIES, JW ;
ROS, HH ;
BOOIJ, LHDJ .
BRITISH JOURNAL OF ANAESTHESIA, 1986, 58 (10) :1100-1103
[5]   UNDERSTANDING THE DOSE-EFFECT RELATIONSHIP - CLINICAL-APPLICATION OF PHARMACOKINETIC-PHARMACODYNAMIC MODELS [J].
HOLFORD, NHG ;
SHEINER, LB .
CLINICAL PHARMACOKINETICS, 1981, 6 (06) :429-453
[6]  
Kansanaho M, 1996, ANAESTHESIA, V51, P133
[7]   QUANTIFYING THE EFFECT OF ENFLURANE ON ATRACURIUM INFUSION REQUIREMENTS [J].
KANSANAHO, M ;
OLKKOLA, KT .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1995, 42 (02) :103-108
[8]   Performance assessment of a fuzzy controller for atracurium-induced neuromuscular block [J].
Mason, DG ;
Edwards, ND ;
Linkens, DA ;
Reilly, CS .
BRITISH JOURNAL OF ANAESTHESIA, 1996, 76 (03) :396-400
[9]  
MCLEOD AD, 1989, BRIT J ANAESTH, V63, P31
[10]   PHARMACODYNAMICS OF MIVACURIUM IN CHILDREN, USING A COMPUTER-CONTROLLED INFUSION [J].
MERETOJA, OA ;
OLKKOLA, KT .
BRITISH JOURNAL OF ANAESTHESIA, 1993, 71 (02) :232-237