Comparison of free-hand and computer assisted cup placement in total hip arthroplasty -: a multi-center study

被引:18
作者
Saxler, G
Marx, A
Vandevelde, D
Langlotz, U
Tannast, M
Wiese, M
Michaelis, U
Kemper, G
Grützner, PA
Steffen, R
von Knoch, M
Holland-Letz, T
Bernsmann, K
机构
[1] Univ Duisburg Essen, Orthopad Klin & Poliklin, D-45122 Essen, Germany
[2] Eeuwfeestklin Antwerpen, Klin Orthopad Chirurg & Traumatol, Antwerp, Belgium
[3] Univ Bern, Inselspital, Klin & Poliklin Orthopad, CH-3010 Bern, Switzerland
[4] Ruhr Univ Bochum, St Josef Hosp, Orthopad Klin & Poliklin, Bochum, Germany
[5] Alfried Krupp Hosp, Klin Orthopad & Sportmed, Essen, Germany
[6] Bethesda Krankenhaus Wuppertal, Chirurg Klin, Wuppertal, Germany
[7] Heidelberg Univ, Klin Unfall & Wiederherstellungschirurg, Ludwigshafen, Germany
[8] Marienkrankenhaus Kaiserwerth, Orthopad Klin, Dusseldorf, Germany
[9] Ruhr Univ Bochum, Abt Med Informat Biometr & Epidemiol, Bochum, Germany
[10] Girardet Klin Essen, Orthopad Klin, Essen, Germany
来源
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE | 2004年 / 142卷 / 03期
关键词
conventional total hip arthroplasty; computer-assisted surgery; CT based measurement of cup placement;
D O I
10.1055/s-2004-822696
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aim: The purpose of the current study was to determine the accuracy of free hand and computer-assisted (CAS) cup placement. Material and Methods: Between June 1985 and August 2001, 105 free-hand and from March to November 1999 80 total hip arthroplasties under computer assistance were implanted in the above mentioned centers. To determine the accuracy of the cups, the inclination and anteversion angles were measured. In all cases the cup position was measured with a CT-investigation of the pelvis. Statistical analysis was performed with the F-test. Results: With regard to the inclination and anteversion angles the variability of the cup position was significantly higher in the group of free hand implanted cups. In the CAS group we could not find any "extreme" positions. Conclusion: Using computer-assisted surgery a significantly higher reproducible cup position can be obtained. Long time survey may present a lowering of the rate of early and late complications caused by better prostheses alignment in the follow up.
引用
收藏
页码:286 / 291
页数:6
相关论文
共 34 条
[1]
[Anonymous], 1992, SOCIOLOGICA, V7
[2]
Bernsmann K, 2001, Z ORTHOP GRENZGEB, V139, P512
[3]
2,012 TOTAL HIP ARTHROPLASTIES - STUDY OF POSTOPERATIVE COURSE AND EARLY COMPLICATIONS [J].
COVENTRY, MB ;
BECKENBAUGH, RD ;
NOLAN, DR ;
ILSTRUP, DM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1974, A 56 (02) :273-284
[4]
CUNNINGHAM P, 1922, PELVIS, P255
[5]
DORR LD, 1983, CLIN ORTHOP RELAT R, V173, P151
[6]
The effect of hospital-type and operating volume on the survival of hip replacements -: A review of 39,505 primary total hip replacements reported to the Norwegian Arthroplasty Register, 1988-1996 [J].
Espehaug, B ;
Havelin, LI ;
Engesæter, LB ;
Vollset, SE .
ACTA ORTHOPAEDICA SCANDINAVICA, 1999, 70 (01) :12-18
[7]
FACKLER CD, 1980, CLIN ORTHOP RELAT R, V151, P169
[8]
Garcia-Cimbrelo E, 1992, J Arthroplasty, V7, P149, DOI 10.1016/0883-5403(92)90008-E
[9]
Accuracy of intraoperative assessment of acetabular prosthesis placement [J].
Hassan, DM ;
Johnston, GHF ;
Dust, WNC ;
Watson, G ;
Dolovich, AT .
JOURNAL OF ARTHROPLASTY, 1998, 13 (01) :80-84
[10]
Hirakawa K, 2001, CLIN ORTHOP RELAT R, P135