Accuracy of dobutamine technetium 99m sestamibi SPECT imaging for the diagnosis of single-vessel coronary artery disease: Comparison with echocardiography

被引:15
作者
Elhendy, A
van Domburg, RT
Bax, JJ
Poldermans, D
Sozzi, FB
Roelandt, JRTC
机构
[1] Univ Rotterdam Hosp, Thoraxctr, Rotterdam, Netherlands
[2] Univ Rotterdam Hosp, Dept Nucl Med, Rotterdam, Netherlands
关键词
D O I
10.1067/mhj.2000.101213
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Recent experimental studies have shown that technetium 99m methoxyisobutyl isonitrile (MIBI) underestimates flow heterogeneity induced by dobutamine and that this might have an impact on the sensitivity of dobutamine MIBI in patients with single-vessel coronary artery disease (CAD). This study compares the accuracy of dobutamine MIBI single-photon emission computed tomography (SPECT) and simultaneous echocardiography in the diagnosis of single-vessel CAD, Methods and Results Ninety-one patients (age 57 +/- 12 years) with single-vessel CAD or without significant CAD were studied with dobutamine (up to 40 mu g/kg per minute)-atropine (up to 1 mg) stress echocardiography (DSE) and simultaneous MIBI SPECT imaging. CAD was predicted on the basis of myocardial ischemia (transient wall motion abnormalities by DSE and reversible perfusion defects by MIBI). Ischemia was detected by MIBI in 30 of the 54 patients with and in 10 of the 37 patients without significant single-vessel CAD (sensitivity 56%, confidence interval [CI] 45 to 66; specificity 73%, CI 64 to 82; accuracy 63%, CI 53 to 73). Ischemia was detected by DSE in 30 patients with and in 6 patients without significant CAD (sensitivity of DSE 56%, CI 45 to 66; specificity 84%, CI 76 to 91; accuracy 67%, CI 57 to 77, P = not significant vs MIBI). For both imaging methods, sensitivity was significantly higher in patients with left anterior descending than in patients with left circumflex or right coronary artery stenosis (75% vs 40%, P < .05). The addition of echocardiography to MIBI did not improve the diagnostic accuracy (68% CI 59 to 78, P = not significant vs DSE or MIBI alone). Conclusions DSE and MIBI SPECT imaging have similar moderate sensitivity For the diagnosis of single-vessel CAD. Sensitivity of each of these techniques is higher in patients with left anterior descending than in patients with left circumflex or right coronary artery stenosis. There is no improvement of diagnostic accuracy by use of the combination of both techniques.
引用
收藏
页码:224 / 230
页数:7
相关论文
共 25 条
[1]   QUANTITATIVE CORONARY ANGIOGRAPHY IN THE ESTIMATION OF THE FUNCTIONAL-SIGNIFICANCE OF CORONARY STENOSIS - CORRELATIONS WITH DOBUTAMINE-ATROPINE STRESS TEST [J].
BAPTISTA, J ;
ARNESE, M ;
ROELANDT, JRTC ;
FIORETTI, P ;
KEANE, D ;
ESCANED, J ;
BOERSMA, E ;
DIMARIO, C ;
SERRUYS, PW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (06) :1434-1439
[2]  
Calnon DA, 1997, CIRCULATION, V96, P2353
[3]  
Elhendy A, 1996, J NUCL MED, V37, P1951
[4]  
Elhendy A, 1998, J NUCL MED, V39, P1662
[5]   Accuracy of dobutamine stress echocardiography for the diagnosis of coronary artery stenosis in patients with myocardial infarction: The impact of extent and severity of left ventricular dysfunction [J].
Elhendy, A ;
vanDomburg, RT ;
Roelandt, JRTC ;
Geleijnse, ML ;
Cornel, JH ;
ElSaid, GM ;
Fioretti, PM .
HEART, 1996, 76 (02) :123-128
[6]   Comparison of dobutamine stress echocardiography and 99m-technetium sestamibi SPECT myocardial perfusion scintigraphy for predicting extent of coronary artery disease in patients with healed myocardial infarction healed myocardial infarction [J].
Elhendy, A ;
Geleijnse, ML ;
Roelandt, JRTC ;
vanDomburg, RT ;
TenCate, FJ ;
Nierop, PR ;
Bax, JJ ;
ElRefaee, M ;
Ibrahim, MM ;
ElSaid, GM ;
Fioretti, PM .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (01) :7-12
[7]   ATROPINE INCREASES THE ACCURACY OF DOBUTAMINE STRESS ECHOCARDIOGRAPHY IN PATIENTS TAKING BETA-BLOCKERS [J].
FIORETTI, PM ;
POLDERMANS, D ;
SALUSTRI, A ;
FORSTER, T ;
BELLOTTI, P ;
BOERSMA, E ;
MCNEILL, AJ ;
ELSAID, ESM ;
ROELANDT, JRTC .
EUROPEAN HEART JOURNAL, 1994, 15 (03) :355-360
[8]   SIMULTANEOUS DOBUTAMINE STRESS ECHOCARDIOGRAPHY AND TC-99M ISONITRILE SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY IN PATIENTS WITH SUSPECTED CORONARY-ARTERY DISEASE [J].
FORSTER, T ;
MCNEILL, AJ ;
SALUSTRI, A ;
REIJS, AEM ;
ELSAID, EM ;
ROELANDT, JRTC ;
FIORETTI, PM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (07) :1591-1596
[9]   Methodology, feasibility, safety and diagnostic accuracy of dobutamine stress echocardiography [J].
Geleijnse, ML ;
Fioretti, PM ;
Roelandt, JRTC .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (03) :595-606
[10]  
GUNALP B, 1993, J NUCL MED, V34, P889