Biodegradable scleral implants as new triamcinolone acetonide delivery systems

被引:33
作者
Felt-Baeyens, O.
Eperon, S.
Mora, P.
Limal, D.
Sagodira, S.
Breton, P.
Simonazzi, B.
Bossy-Nobs, L.
Guex-Crosier, Y.
Gurny, R.
机构
[1] Univ Geneva, Sch Pharmaceut Sci, Dept Pharmaceut & Biopharmaceut, CH-1211 Geneva 4, Switzerland
[2] Univ Lausanne, CH-1211 Geneva 4, Switzerland
[3] Jules Gonin Eye Hosp, CH-1000 Lausanne 7, Switzerland
[4] Virsol, F-75116 Paris, France
关键词
scleral implant; biodegradable polymer; biocompatibility; triamcinolone acetonide;
D O I
10.1016/j.ijpharm.2006.05.053
中图分类号
R9 [药学];
学科分类号
1007 [药学];
摘要
The goal of this study was to develop ocular scleral implants able to release triamcinolone acetonide (TA) overall several months. Scleral discs were manufactured by a compression- molding method using a new synthetic polymer, poly(methylidene malonate) (PMM2.1.2), as matrix. Implants with good mechanical properties adapted for in vivo implantation have been obtained when using high M-w PMM2.1.2 (100,000-150,000 Da) associated with ethoxylated derivatives of stearic acid (Simulsol (R)) or oligomers of methylidene malonate as plasticizer. After implantation in rabbit eyes, scleral implants showed a good ocular biocompatibility. Indeed, the clinical follow-up and ocular inflammation parameters, such as inflammatory cell number and protein content in aqueous humor, demonstrated that implants were well tolerated and did not provoke abnormal inflammation. Implants were able to release significant concentrations of TA in the vitreous and the sclera throughout 5 weeks. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:6 / 12
页数:7
相关论文
共 40 条
[1]
Transscleral drug delivery to the retina and choroid [J].
Ambati, J ;
Adamis, AP .
PROGRESS IN RETINAL AND EYE RESEARCH, 2002, 21 (02) :145-151
[2]
CONTROL OF CYTOMEGALOVIRUS RETINITIS USING SUSTAINED-RELEASE OF INTRAOCULAR GANCICLOVIR [J].
ANAND, R ;
NIGHTINGALE, SD ;
FISH, RH ;
SMITH, TJ ;
ASHTON, P .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (02) :223-227
[3]
Intraocular concentration and pharmacokinetics of triamcinolone acetonide after a single intravitreal injection [J].
Beer, PM ;
Bakri, SJ ;
Singh, RJ ;
Liu, WG ;
Peters, GB ;
Miller, M .
OPHTHALMOLOGY, 2003, 110 (04) :681-686
[4]
BIOCOMPATIBILITY OF A NEW SEMISOLID BIOERODIBLE POLY(ORTHO ESTER) INTENDED FOR THE OCULAR DELIVERY OF 5-FLUOROURACIL [J].
BERNATCHEZ, SF ;
MERKLI, A ;
MINH, TL ;
TABATABAY, C ;
ANDERSON, JM ;
GURNY, R .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (09) :1037-1046
[5]
Tetracycline-HCl-loaded poly(DL-lactide-co-glycolide) microspheres prepared by a spray drying technique:: influence of γ-irradiation on radical formation and polymer degradation [J].
Bittner, B ;
Mäder, K ;
Kroll, C ;
Borchert, HH ;
Kissel, T .
JOURNAL OF CONTROLLED RELEASE, 1999, 59 (01) :23-32
[6]
BODKER FS, 1993, OPHTHALMIC SURG LAS, V24, P453
[7]
BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
[8]
Physico-chemical characterization, preparation and performance of poly (methylidene malonate 2.1.2) nanoparticles [J].
Breton, P ;
Guillon, X ;
Roy, D ;
Lescure, F ;
Riess, G ;
Bru, N ;
Roques-Carmes, C .
BIOMATERIALS, 1998, 19 (1-3) :271-281
[9]
BRETON P, 1994, NANOPARTICLES RECENT, V4, P161
[10]
Gene expression signature of fibroblast serum response predicts human cancer progression: Similarities between tumors and wounds [J].
Chang, HY ;
Sneddon, JB ;
Alizadeh, AA ;
Sood, R ;
West, RB ;
Montgomery, K ;
Chi, JT ;
van de Rijn, M ;
Botstein, D ;
Brown, PO .
PLOS BIOLOGY, 2004, 2 (02) :206-214