Matching of digitised brain atlas to magnetic resonance images

被引:8
作者
Sorlie, C
Bertrand, O
Yvert, B
Froment, JC
Pernier, J
机构
[1] INSERM, U280, BRAIN SIGNALS & PROC LAB, F-69424 LYON 03, FRANCE
[2] UNIV LYON 1, F-69365 LYON, FRANCE
[3] NATL HOSP NEUROL & NEUROSURG, DEPT RADIOL, MRI LAB, LYON, FRANCE
关键词
digitised brain atlas; MRI; brain anatomy; image matching;
D O I
10.1007/BF02530044
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A method has been developed to match a standard digitised brain atlas onto MR images for identification of cerebral structures in anatomical images. This method uses, first, a three-dimensional crude registration based on the proportional system of Talairach. Then, a two-dimensional refined registration is performed using a deformation function based on a set of homologous landmarks on both images (MR and atlas). Displacements vectors are computed between each corresponding landmark. These vectors are interpolated by thin-plate splines, generating an unwarping function defined on the whole image. This function can then be applied on any structure of the atlas. An evaluation of the matching procedure has been performed. First, the influence of the choice of the landmarks has been evaluated for the fine registration method. The latter has been then compared to the crude registration method considered as a classical reference method. These results show the advantages of the fine registration approach.
引用
收藏
页码:239 / 245
页数:7
相关论文
共 27 条
[1]   A COMPUTERIZED SYSTEM FOR THE ELASTIC MATCHING OF DEFORMED RADIOGRAPHIC IMAGES TO IDEALIZED ATLAS IMAGES [J].
BAJCSY, R ;
LIEBERSON, R ;
REIVICH, M .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1983, 7 (04) :618-625
[2]  
BAJCSY R, 1985, POSITRON EMISSION TO, P119
[3]   A COMPUTERIZED ADJUSTABLE BRAIN ATLAS [J].
BOHM, C ;
GREITZ, T ;
ERIKSSON, L .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1989, 15 (11) :687-689
[4]  
BOHM C, 1985, METABOLISM HUMAN BRA, P85
[5]  
BOOKSTEIN FL, 1991, LECT NOTES COMPUT SC, V511, P326, DOI 10.1007/BFb0033763
[6]  
BOOKSTEIN FL, 1990, 3 DIMENSIONAL NEUROI, P235
[7]   AUTOMATIC 3D INTERSUBJECT REGISTRATION OF MR VOLUMETRIC DATA IN STANDARDIZED TALAIRACH SPACE [J].
COLLINS, DL ;
NEELIN, P ;
PETERS, TM ;
EVANS, AC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (02) :192-205
[8]   EVALUATION OF ELASTIC MATCHING SYSTEM FOR ANATOMIC (CT, MR) AND FUNCTIONAL (PET) CEREBRAL IMAGES [J].
DANN, R ;
HOFORD, J ;
KOVACIC, S ;
REIVICH, M ;
BAJCSY, R .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (04) :603-611
[9]  
DUCHON J, 1976, REV FR AUTOMAT INFOR, V10, P5
[10]   ANATOMICAL-FUNCTIONAL CORRELATION USING AN ADJUSTABLE MRI-BASED REGION OF INTEREST ATLAS WITH POSITRON EMISSION TOMOGRAPHY [J].
EVANS, AC ;
BEIL, C ;
MARRETT, S ;
THOMPSON, CJ ;
HAKIM, A .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1988, 8 (04) :513-530