Alterations of mouse lung tissue dimensions during processing for morphometry: A comparison of methods

被引:82
作者
Schneider, Jan Philipp [1 ]
Ochs, Matthias [1 ,2 ,3 ]
机构
[1] Hannover Med Sch, Inst Funct & Appl Anat, D-30625 Hannover, Germany
[2] Biomed Res Endstage & Obstruct Lung Dis Hannover, Hannover, Germany
[3] REBIRTH Cluster Excellence, Hannover, Germany
关键词
mouse lung; stereology; shrinkage; embedding; fixation; UNBIASED STEREOLOGICAL ESTIMATION; PATHOLOGICAL RESEARCH; OSMIUM-TETROXIDE; BASIC PRINCIPLES; FIXATION; SHRINKAGE; NUMBER; VOLUME; MICROSCOPY; GLUTARALDEHYDE;
D O I
10.1152/ajplung.00329.2013
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Preservation of original tissue dimensions is an essential prerequisite for morphometric studies. Shrinkage occurring during tissue processing for histology may severely influence the appearance of structures seen under the microscope and stereological calculations. Therefore, shrinkage has to be avoided so that estimates obtained by application of unbiased stereology are indeed unbiased. The present study investigates the alterations of tissue dimensions of mouse lung samples during processing for histology. Different fixatives as well as embedding protocols are considered. Mouse lungs were fixed by instillation of either 4% formalin or a mixture of 1.5% glutaraldehyde/1.5% formaldehyde. Tissue blocks were sampled according to principles of stereology for embedding in paraffin, glycol methacrylate without treatment with osmium tetroxide and uranyl acetate, and glycol methacrylate including treatment with osmium tetroxide and uranyl acetate before dehydration. Shrinkage was investigated by stereological measurements of dimensional changes of tissue cut faces. Results show a shrinkage of the cut face areas of roughly 40% per lung during paraffin embedding, 30% during "simple" glycol methacrylate embedding, and <3% during osmium tetroxide/uranyl acetate/glycol methacrylate embedding. Furthermore, the superiority of the glutaraldehyde- containing fixative regarding shrinkage is demonstrated. In conclusion, the use of a glutaraldehyde-containing fixative and embedding in glycol methacrylate with previous treatment of the samples with osmium tetroxide and uranyl acetate before dehydration is recommended for stereological studies of the mouse lung.
引用
收藏
页码:L341 / L350
页数:10
相关论文
共 62 条
[1]  
[Anonymous], 1979, LONDON STEREOL METHO
[2]  
[Anonymous], 1980, STEREOLOGICAL METHOD
[3]   PERFUSION FIXATION OF LUNGS FOR STRUCTURE-FUNCTION ANALYSIS - CREDITS AND LIMITATIONS [J].
BACHOFEN, H ;
AMMANN, A ;
WANGENSTEEN, D ;
WEIBEL, ER .
JOURNAL OF APPLIED PHYSIOLOGY, 1982, 53 (02) :528-533
[4]   CERVICAL TISSUE SHRINKAGE BY FORMALDEHYDE FIXATION, PARAFFIN WAX EMBEDDING, SECTION CUTTING AND MOUNTING [J].
BOONSTRA, H ;
OOSTERHUIS, JW ;
OOSTERHUIS, AM ;
FLEUREN, GJ .
VIRCHOWS ARCHIV A-PATHOLOGICAL ANATOMY AND HISTOPATHOLOGY, 1983, 402 (02) :195-201
[5]  
BOYDE A, 1980, Scanning Electron Microscopy, P117
[6]  
Boyde A., 1977, Proceedings of the 10th Annual Scanning Electron Microscopy Symposium, P507
[7]  
Boyde A, 1980, SCANNING ELECTRON MI, V2, P132
[8]   A comparison of fixation methods on lung morphology in a murine model of emphysema [J].
Braber, S. ;
Verheijden, K. A. T. ;
Henricks, P. A. J. ;
Kraneveld, A. D. ;
Folkerts, G. .
AMERICAN JOURNAL OF PHYSIOLOGY-LUNG CELLULAR AND MOLECULAR PHYSIOLOGY, 2010, 299 (06) :L843-L851
[9]   THE IMPACT OF RECENT STEREOLOGICAL ADVANCES ON QUANTITATIVE STUDIES OF THE NERVOUS-SYSTEM [J].
BRAENDGAARD, H ;
GUNDERSEN, HJG .
JOURNAL OF NEUROSCIENCE METHODS, 1986, 18 (1-2) :39-78
[10]   RECENT STEREOLOGICAL METHODS FOR CELL BIOLOGY - A BRIEF SURVEY [J].
CRUZORIVE, LM ;
WEIBEL, ER .