Performance of 21-mm size perimount aortic bioprosthesis in the elderly

被引:13
作者
Bortolotti, U
Scioti, G
Milano, A
De Carlo, M
Codecasa, R
Nardi, C
Tartarini, G
机构
[1] Univ Pisa, Sch Med, Dept Cardiol Angiol & Pneumol, Sect Cardiac Surg, I-56100 Pisa, Italy
[2] Univ Pisa, Sch Med, Dept Cardiol Angiol & Pneumol, Cardiol Sect, I-56100 Pisa, Italy
关键词
D O I
10.1016/S0003-4975(99)00856-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Aortic valve replacement in elderly patients with a small aortic annulus may pose difficult problems in terms of prosthesis selection. We have evaluated the hemodynamic performance of the 21-mm Carpentier-Edwards Perimount bioprosthesis implanted in elderly patients. Methods. From July 1996 to June 1998, 19 patients (17 women acid 2 men, mean age 76 +/- 4 years and mean body surface area 1.73 +/- 0.13 m(2)), had aortic valve replacement with a 21-mm Carpentier-Edwards Perimount bioprosthesis. The hemodynamic performance of the valve was evaluated in 16 patients, who completed at least a 6-month follow-up interval, with transthoracic color; Doppler echocardiography with particular reference to peak and mean transprosthetic gradients, effective orifice area index, and regression of left ventricular mass index. Results. There were no late deaths and no major postoperative complications. At a mean follow-up of 12 +/- 7 months, compared to discharge, all patients showed clinical improvement with a significant reduction of Beak gradient (from 23 +/- 4 to 21 +/- 6 mm Hg, p = 0.04) and left ventricular mass index (from 181 +/- 23 to 153 +/- 20 g/m(2); p < 0.001), whereas mean gradient (from 13 +/- 3 to 13 +/- 4 mm Hg, p = not significant) and effective orifice area index (from 1.12 +/- 0.34 to 1.13 +/- 0.28 cm(2)/m(2), p = not significant) remained substantially unchanged. Conclusions. The use of a 21-mm Carpentier-Edwards Perimount bioprosthesis is associated with low transprosthetic gradients and significant reduction in left ventricular hypertrophy after aortic valve replacement. The results of our study suggest that a 21-m Carpentier-Edwards Perimount bioprosthesis should be considered a valid option in elderly patients with aortic valve disease and a small aortic annulus. (C) 2000 by The Society of Thoracic Surgeons.
引用
收藏
页码:47 / 50
页数:4
相关论文
共 23 条
[1]   CLINICAL AND HEMODYNAMIC PERFORMANCE OF THE 19-MM CARPENTIER-EDWARDS PORCINE BIOPROSTHESIS [J].
BOJAR, RM ;
RASTEGAR, H ;
PAYNE, DD ;
MACK, CA ;
SCHWARTZ, SL .
ANNALS OF THORACIC SURGERY, 1993, 56 (05) :1141-1147
[2]   FAILURE OF HANCOCK PERICARDIAL XENOGRAFTS - IS PROPHYLACTIC BIOPROSTHETIC REPLACEMENT JUSTIFIED [J].
BORTOLOTTI, U ;
MILANO, A ;
GUERRA, F ;
MAZZUCCO, A ;
MOSSUTO, E ;
THIENE, G ;
GALLUCCI, V .
ANNALS OF THORACIC SURGERY, 1991, 51 (03) :430-437
[3]  
Bortolotti U, 1988, Eur J Cardiothorac Surg, V2, P458, DOI 10.1016/1010-7940(88)90052-8
[4]  
Bortolotti U, 1998, J HEART VALVE DIS, V7, P299
[5]  
BORTOLOTTI U, 1987, J THORAC CARDIOV SUR, V94, P200
[6]  
DAVID TE, 1990, J THORAC CARDIOV SUR, V99, P113
[7]  
Deiwick M, 1995, CARDIOL ELDER, V3, P381
[8]  
DePaulis R, 1996, J HEART VALVE DIS, V5, pS339
[9]   ECHOCARDIOGRAPHIC DETERMINATION OF LEFT-VENTRICULAR MASS IN MAN - ANATOMIC VALIDATION OF METHOD [J].
DEVEREUX, RB ;
REICHEK, N .
CIRCULATION, 1977, 55 (04) :613-618
[10]   Guidelines for reporting morbidity and mortality after cardiac valvular operations [J].
Edmunds, LH ;
Clark, RE ;
Cohn, LH ;
Grunkemeier, GL ;
Miller, C ;
Weisel, RD .
ANNALS OF THORACIC SURGERY, 1996, 62 (03) :932-935