A biomechanical analysis of sublaminar and subtransverse process fixation using metal wires and polyethylene cables

被引:23
作者
Fujita, Masaru
Diab, Mohammad
Xu, Zheng
Puttlitz, Christian M.
机构
[1] Colorado State Univ, Orthopaed Bioengn Res Lab, Dept Mech Engn, Ft Collins, CO 80523 USA
[2] Univ Calif San Francisco, Dept Orthopaed Surg, San Francisco, CA 94143 USA
关键词
biomechanics; thoracic spine; sublaminar; subtransverse process; ultra-high molecular weight polyethylene cable;
D O I
10.1097/01.brs.0000232831.63589.22
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. An in vitro biomechanical calf thoracic spine study. Objective. To evaluate the biomechanical stability of sublaminar and subtransverse process fixation using stainless steel wires and ultra-high molecular weight polyethylene (UHMWPE) cables. Summary of Background Data. It is commonly held that transverse process fixation provides less stability than sublaminar fixation. To our knowledge, this is the first biomechanical study to compare the stability afforded by sublaminar fixation and subtransverse process fixation using metal wire and UHMWPE cable before and after cyclic loading. Methods. There were 6 fresh-frozen calf thoracic spines (T4-T9) used to determine the sublaminar fixation stiffness and subtransverse process fixation stiffness in each group. Double strands of 18-gauge stainless steel wire, 3 and 5 mm-width UHMWPE cable (Nesplon (R); Alfresa, Inc., Osaka, Japan) were applied to each spine. Cyclic pure flexion-extension moment loading (2 Nm, 0.5 Hz, 5000 cycles) was applied after the initial stability was analyzed by measuring the range of motion. Statistical analyses were used to delineate differences between the various experimental groups. Results. Subtransverse process wiring was more stable than sublaminar wiring after cyclic loading in flexion-extension (P < 0.05). There were no significant differences between each group in lateral bending and axial rotation after cyclic loading. Sublaminar stainless steel wiring was more stable than sublaminar 3 and 5-mm cable before and after cyclic loading in axial rotation (P < 0.01). Acute subtransverse process fixation using 3-mm cable was less stable after cyclic loading in axial rotation (P < 0.05). All other groups did not produce statistically significant differences. Conclusions. Subtransverse process fixation provides at least as much stability as sublaminar fixation. A 5-mm UHMWPE cable and stainless steel wire result in equivalent sublaminar and subtransverse process stability.
引用
收藏
页码:2202 / 2208
页数:7
相关论文
共 33 条
[1]
Safety and efficacy of isola instrumentation and arthrodesis for adolescent idiopathic scoliosis - Two- to 12-year follow-up [J].
Asher, M ;
Lai, SM ;
Burton, D ;
Manna, B ;
Cooper, A .
SPINE, 2004, 29 (18) :2013-2023
[2]
Hardware complications in scoliosis surgery [J].
Bagchi, K ;
Mohaideen, A ;
Thomson, JD ;
Foley, LC .
PEDIATRIC RADIOLOGY, 2002, 32 (07) :465-475
[3]
LATE COMPLICATIONS DUE TO WIRE BREAKAGE IN SEGMENTAL SPINAL INSTRUMENTATION - REPORT OF 2 CASES [J].
BERNARD, TN ;
JOHNSTON, CE ;
ROBERTS, JM ;
BURKE, SW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1983, 65 (09) :1339-1345
[4]
Apical sublaminar wires versus pedicle screws - Which provides better results for surgical correction of adolescent idiopathic scoliosis? [J].
Cheng, I ;
Kim, Y ;
Gupta, MC ;
Bridwell, KH ;
Hurford, RK ;
Lee, SS ;
Theerajunyaporn, T ;
Lenke, LG .
SPINE, 2005, 30 (18) :2104-2112
[5]
AN ANATOMICAL COMPARISON OF THE HUMAN AND BOVINE THORACOLUMBAR SPINE [J].
COTTERILL, PC ;
KOSTUIK, JP ;
DANGELO, G ;
FERNIE, GR ;
MAKI, BE .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1986, 4 (03) :298-303
[6]
Comparative mechanical properties of spinal cable and wire fixation systems [J].
Dickman, CA ;
Papadopoulos, SM ;
Crawford, NR ;
Brantley, AGU ;
Gealer, RL .
SPINE, 1997, 22 (06) :596-604
[7]
Doran SE, 1996, NEUROSURGERY, V38, P493
[8]
DOVE J, 1987, ORTHOPEDICS, V10, P955
[9]
Erel N, 2003, ACTA ORTHOP SCAND, V74, P312
[10]
A study of the mechanical stability of scoliosis constructs using variable numbers of sublaminar wires [J].
Gadgil, A ;
Ahmed, EB ;
Rahmatalla, A ;
Dove, J ;
Maffulli, N .
EUROPEAN SPINE JOURNAL, 2002, 11 (04) :321-+