Sensitive cadmium potentiometric sensor based on 4-hydroxy salophen as a fast tool for water samples analysis

被引:25
作者
Ensafi, Ali A. [1 ]
Meghdadi, S. [1 ]
Sedighi, S. [1 ]
机构
[1] Isfahan Univ Technol, Dept Chem, Esfahan 8415683111, Iran
关键词
Cadmium(II) sensor; 4-hydroxy salophen; Potentiometry; ION-SELECTIVE ELECTRODES; BULK OPTODES; HEAVY-METALS; MEMBRANE; IONOPHORES; CD(II); SITES; CHROMATOGRAPHY; COMPLEX; LEAD;
D O I
10.1016/j.desal.2008.06.002
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A PVC membrane with 4-hydroxy salophen as an ionophore along with sodium tetraphenyl borate (NaTPB) as an anion excluder and dibutyl phthalate as a solvent mediator in the ratio 28.7:3.3:63.2:4.7 (w/w) (PVC-NaTPB-DBP-ionophore) exhibits good properties with a Nemstian response of 30.1 +/- 1.0 mV per decade of activity for Cd(II) ions and a working concentration range of 1.0x 10(-6)-1.0x10(-1) mol L-1 Cd(II). The limit of detection was 8.4x10(-7) mol L-1 Cd(II). The sensor has a fast response time of 20 s and can be used for at least 8 weeks without any divergence in potential. The electrode can be used in the pH range of 2.8-8.1. The selectivity coefficients for Cd(II) relative to a numbers of potential interfering ions were investigated. The proposed sensor shows fairly good discriminating ability towards Cd(II) ions in comparison with some alkali, alkaline earth, transition and heavy metal ions. The practical utility of the sensor has been demonstrated by using it successfully as an indicator electrode in the potentiometric titration of Cd(II) with EDTA and also for the direct determination of Cd(11) in water and in waste water samples.
引用
收藏
页码:336 / 345
页数:10
相关论文
共 50 条
[1]  
Akba O, 2003, FRESEN ENVIRON BULL, V12, P1412
[2]   Cationic or anionic sites?: Selectivity optimization of ion-selective electrodes based on charged ionophores [J].
Amemiya, S ;
Bühlmann, P ;
Pretsch, E ;
Rusterholz, B ;
Umezawa, Y .
ANALYTICAL CHEMISTRY, 2000, 72 (07) :1618-1631
[3]   Synthesis and spectroscopic characterization of [CoIII(salophen)(amine)2]ClO4 (amine = morpholine, pyrrolidine, and piperidine) complexes.: The crystal structures of [CoIII(salophen)(morpholine)2]ClO4 and [CIII(salophen)(pyrrolidine)2]ClO4 [J].
Amirnasr, M ;
Schenk, KJ ;
Gorji, A ;
Vafazadeh, R .
POLYHEDRON, 2001, 20 (7-8) :695-702
[4]  
AMMANN D, 1986, ION SELECTIVE ELECT
[5]   ANION-SELECTIVE MEMBRANE ELECTRODES BASED ON METALLOPORPHYRINS - THE INFLUENCE OF LIPOPHILIC ANIONIC AND CATIONIC SITES ON POTENTIOMETRIC SELECTIVITY [J].
BAKKER, E ;
MALINOWSKA, E ;
SCHILLER, RD ;
MEYERHOFF, ME .
TALANTA, 1994, 41 (06) :881-890
[6]   Selectivity of potentiometric ion sensors [J].
Bakker, E ;
Pretsch, E ;
Bühlmann, P .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1127-1133
[7]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[8]   Determination of nanomolar concentrations of lead and cadmium by anodic-stripping voltammetry at the silver electrode [J].
Bonfil, Y ;
Kirowa-Eisner, E .
ANALYTICA CHIMICA ACTA, 2002, 457 (02) :285-296
[9]   RECOMMENDED PROCEDURES FOR CALIBRATION OF ION-SELECTIVE ELECTRODES [J].
BUCK, RP ;
COSOFRET, VV .
PURE AND APPLIED CHEMISTRY, 1993, 65 (08) :1849-1858
[10]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687