High density resolution in synchrotron-radiation-based attenuation-contrast microtomography

被引:32
作者
Beckmann, Felix [1 ]
Herzen, Julia [1 ]
Haibel, Astrid [1 ]
Mueller, Bert [2 ]
Schreyer, Andreas [1 ]
机构
[1] GKSS Forschungszentrum Geesthacht GmbH, Inst Mat Res, Geesthacht, Germany
[2] Univ Basel, BMC, Basel, Switzerland
来源
DEVELOPMENTS IN X-RAY TOMOGRAPHY VI | 2008年 / 7078卷
关键词
attenuation contrast; density resolution; synchrotron radiation; tomography; microtomography; spatial resolution;
D O I
10.1117/12.794617
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
During the last few years microtomography using synchrotron radiation (SR) has become a standard technique to characterize samples 3-dimensionally in the fields of biology, medicine and materials science. The GKSS Research Center Geesthacht, Germany, is responsible for developing and running the microtomography experiments at the SR-facility DESY, Hamburg, Germany. The application of SR mu CT using attenuation-contrast at the beamlines W2/HARWI-II and BW2 of the storage ring DORIS III results in high throughput investigations. For achieving tomograms showing not only high spatial resolution but also high density resolution special emphasis was given to the stability of the used monochromators and the calibration of the total system. The influence of the photon statistics from the measurement to the tomograms is simulated and the achieved density resolution is demonstrated showing selected results.
引用
收藏
页数:13
相关论文
共 25 条
[1]  
AMANCIO S, 2008, POLYM DEGRA IN PRESS
[2]   Microtomography using synchrotron radiation at DESY: current status and future developments [J].
Beckmann, F ;
Donath, T ;
Dose, T ;
Lippmann, T ;
Martins, RV ;
Metge, J ;
Schreyer, A .
DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 :1-10
[3]  
Beckmann F, 2000, MATER RES SOC SYMP P, V590, P265
[4]  
BECKMANN F, 2006, P SPIE, V6318
[5]  
BECKMANN F, 2008, NEUTRONS SYNCHROTRON, P287
[6]  
Beckmann F, 2007, AIP CONF PROC, V879, P746
[7]   Automated determination of the center of rotation in tomography data [J].
Donath, T ;
Beckmann, F ;
Schreyer, A .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2006, 23 (05) :1048-1057
[8]   DESIGN AND PERFORMANCE OF THE HIGH-FLUX HIGH-BRIGHTNESS X-RAY WIGGLER BEAMLINE BW2 AT HASYLAB [J].
DRUBE, W ;
SCHULTESCHREPPING, H ;
SCHMIDT, HG ;
TREUSCH, R ;
MATERLIK, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :1668-1670
[9]   The morphology of anisotropic 3D-printed hydroxyapatite scaffolds [J].
Fierz, Fabienne C. ;
Beckmann, Felix ;
Huser, Marius ;
Irsen, Stephan H. ;
Leukers, Barbara ;
Witte, Frank ;
Degistirici, Oezer ;
Andronache, Adrian ;
Thie, Michael ;
Mueller, Bert .
BIOMATERIALS, 2008, 29 (28) :3799-3806
[10]  
Friedrich F., 2008, P SPIE