Conductimetric membrane strip immunosensor with polyaniline-bound gold colloids as signal generator

被引:117
作者
Kim, JH
Cho, JH
Cha, GS
Lee, CW
Kim, HB
Paek, SH
机构
[1] Korea Univ, Grad Sch Biotechnol, Sungbuk Ku, Seoul 136701, South Korea
[2] Kwangwoon Univ, Dept Chem, Seoul 139701, South Korea
[3] Korea Univ, Dept Chem, Chochiwon 339700, Choongnam, South Korea
关键词
immuno-chromatographic assay; conductimetric detection; polyaniline; colloidal gold; membrane electrode;
D O I
10.1016/S0956-5663(99)00063-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
For point-of-care examination, an immuno-chromatographic assay system based on conductimetric detection was investigated by utilizing, as signal generator, colloidal gold with polyaniline bound on the metal surface. Although the gold is a widely used label for antibodies to produce colorimetric signals, the tracer does not lend itself for a suitable electric conduction along the gold particles due to the presence of protein barriers (e.g, immunoglobulin and blocking agent) against electron transfer. To overcome this problem, we introduced a conducting polymer, for instance, polyaniline, as a conductivity-modulating agent on the gold surface after immobilizing an antibody specific to human albumin used as model analyte, This novel signal generator amplified the conductimetric signal 4.7 times compared with the plain gold, and the signal was also maximum 2.3-fold higher than that from the photometric system under the same analytical conditions. The latter effect resulted from an exponential pattern in the dose-response curve of the electric signal that was different from the conventional sigmoidal shape. (C) 2000 Elsevier Science S.A. AU rights reserved.
引用
收藏
页码:907 / 915
页数:9
相关论文
共 36 条
[1]   Effect of selected processing parameters on solution properties and morphology of polyaniline and impact on conductivity [J].
Angelopoulos, M ;
Dipietro, R ;
Zheng, WG ;
MacDiarmid, AG ;
Epstein, AJ .
SYNTHETIC METALS, 1997, 84 (1-3) :35-39
[2]  
BEESLEY JE, 1993, IMMUNOCYTOCHEMISTRY, P151
[3]  
BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
[4]  
BULLOCK CR, 1983, TECHNIQUES IMMUNOCYT, V2, P217
[5]  
BUTLER JE, 1991, IMMUNOCHEMISTRY SOLI, P47
[6]  
CAVELIER G, 1995, BIOELECTROCH BIOENER, V40, P197
[7]  
CHEN R, 1987, CLIN CHEM, V33, P1521
[8]   Molecular-level processing of conjugated polymers .3. Layer-by-layer manipulation of polyaniline via electrostatic interactions [J].
Cheung, JH ;
Stockton, WB ;
Rubner, MF .
MACROMOLECULES, 1997, 30 (09) :2712-2716
[9]   POLYANILINE - PROTONIC ACID DOPING OF THE EMERALDINE FORM TO THE METALLIC REGIME [J].
CHIANG, JC ;
MACDIARMID, AG .
SYNTHETIC METALS, 1986, 13 (1-3) :193-205
[10]   A low-cost and high-performance conductivity meter [J].
daRocha, RT ;
Gutz, IGR ;
doLago, CL .
JOURNAL OF CHEMICAL EDUCATION, 1997, 74 (05) :572-574