Simultaneous selected reaction monitoring, MS/MS and MS3 quantitation for the analysis of pharmaceutical compounds in human plasma using chip-based infusion

被引:39
作者
Leuthold, LA
Grivet, C
Allen, M
Baumert, M
Hopfgartner, G
机构
[1] Univ Geneva, Sch Pharm, Lab Pharmaceut Analyt Chem Life Sci Mass Spectrom, CH-1211 Geneva 4, Switzerland
[2] Advion BioSci, Norwich NR9 3DB, Norfolk, England
关键词
D O I
10.1002/rcm.1587
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An assay method with mass spectrometric detection was developed for the quantitative analysis of a pharmaceutical compound and its major metabolite in human plasma using chip-based infusion. Liquid-liquid extraction sample preparation was found to be essential to minimize matrix suppression and to achieve a limit of quantitation (LOQ) of 2.5 ng/mL using a 100 muL plasma aliquot. The potential for simultaneous quantitation in selected reaction monitoring (SRM), tandem mass spectrometry (MS/MS) (enhanced product ion), and MS3 was investigated and found to be very beneficial in improving assay selectivity. A novel concept for monitoring quantitative assay performance using a SRM/MS3 ratio is proposed. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:1995 / 2000
页数:6
相关论文
共 12 条
[1]  
Chen S, 2001, RAPID COMMUN MASS SP, V15, P159, DOI 10.1002/1097-0231(20010130)15:2<159::AID-RCM210>3.0.CO
[2]  
2-W
[3]   Demonstration of direct bioanalysis of drugs in plasma using nanoelectrospray infusion from a silicon chip coupled with tandem mass spectrometry [J].
Dethy, JM ;
Ackermann, BL ;
Delatour, C ;
Henion, JD ;
Schultz, GA .
ANALYTICAL CHEMISTRY, 2003, 75 (04) :805-811
[4]   A new linear ion trap mass spectrometer [J].
Hager, JW .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (06) :512-526
[5]   Quantitative high-throughput analysis of drugs in biological matrices by mass spectrometry [J].
Hopfgartner, G ;
Bourgogne, E .
MASS SPECTROMETRY REVIEWS, 2003, 22 (03) :195-214
[6]   Rapid screening and characterization of drug metabolites using a new quadrupole-linear ion trap mass spectrometer [J].
Hopfgartner, G ;
Husser, C ;
Zell, M .
JOURNAL OF MASS SPECTROMETRY, 2003, 38 (02) :138-150
[7]   Quantitation of midazolam in human plasma by automated chip-based infusion nanoelectrospray tandem mass spectrometry [J].
Kapron, JT ;
Pace, E ;
Van Pelt, CK ;
Henion, J .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (18) :2019-2026
[8]   Development of high-performance liquid chromatography tandem mass spectrometric methods for the determination of a new oxytocin receptor antagonist (L-368,899) extracted from human plasma and urine: a case of lack of specificity due to the presence of metabolites [J].
Matuszewski, BK ;
Chavez-Eng, CM ;
Constanzer, ML .
JOURNAL OF CHROMATOGRAPHY B, 1998, 716 (1-2) :195-208
[9]   Particle discriminator interface for nanoflow ESI-MS [J].
Schneider, BB ;
Baranov, VI ;
Javaheri, H ;
Covey, TR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2003, 14 (11) :1236-1246
[10]  
Zell M, 1997, RAPID COMMUN MASS SP, V11, P1107, DOI 10.1002/(SICI)1097-0231(19970630)11:10<1107::AID-RCM959>3.0.CO