Telemedicine improves diagnosis of essential hypertension compared with usual care

被引:25
作者
Rogers, MAM
Buchan, DA
Small, D
Stewart, CM
Krenzer, BE
机构
[1] Med Coll Ohio, Dept Pediat, Joint Res Program Pediat & Family Med, Toledo, OH 43614 USA
[2] SUNY Upstate Med Univ, Syracuse, NY USA
关键词
D O I
10.1258/135763302320939239
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
A randomized controlled trial was conducted to assess the efficacy of a telemedicine service for the diagnosis of essential hypertension. The telemedicine service consisted of using an automatic home blood pressure monitor connected to an ordinary telephone line for the transmission of the data to a central computer. After use of the home monitor for a week, the results were converted to a report form and faxed to the patient's physician. The gold standard for assessment of true hypertension status was 24 h ambulatory blood pressure monitoring. A total of 74 patients from outpatient clinics were randomized into either the telemedicine service or usual care. Use of the telemedicine service significantly improved the detection of essential hypertension compared with usual care: in the telemedicine group, 64% of patients with essential hypertension were diagnosed; in the usual care group, 26% of patients with essential hypertension were diagnosed. Furthermore, diagnosis occurred earlier in the telemedicine group than in patients receiving usual care. Specificity and positive predictive value were similar in the two groups.
引用
收藏
页码:344 / 349
页数:6
相关论文
共 9 条
[1]   Reliability of self-reported blood pressure measurements [J].
Johnson, KA ;
Partsch, DJ ;
Rippole, LL ;
McVey, DM .
ARCHIVES OF INTERNAL MEDICINE, 1999, 159 (22) :2689-2693
[2]  
Mancia G, 1995, J HYPERTENS, V13, P1377
[3]  
National Asthma Education and Prevention Program, 1997, NIH PUBL
[4]  
National Center for Health Statistics, 2001, DHHS PUBL
[5]   Clinical inertia [J].
Phillips, LS ;
Branch, WT ;
Cook, CB ;
Doyle, JP ;
El-Kebbi, IM ;
Gallina, DL ;
Miller, CD ;
Ziemer, DC ;
Barnes, CS .
ANNALS OF INTERNAL MEDICINE, 2001, 135 (09) :825-834
[6]  
PICKERING TG, 1994, LANCET, V344, P31
[7]   A new role for ambulatory blood pressure monitoring? [J].
Pickering, TG .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1997, 278 (13) :1110-1110
[8]   Home monitoring service improves mean arterial pressure in patients with essential hypertension - A randomized, controlled trial [J].
Rogers, MAM ;
Small, D ;
Buchan, DA ;
Butch, CA ;
Stewart, CM ;
Krenzer, BE ;
Husovsky, HL .
ANNALS OF INTERNAL MEDICINE, 2001, 134 (11) :1024-1032
[9]   Validation of A&D UA-767 device for the self-measurement of blood pressure [J].
Rogoza, AN ;
Pavlova, TS ;
Sergeeva, MV .
BLOOD PRESSURE MONITORING, 2000, 5 (04) :227-231