Stent implantation for aortic coarctation and recoarctation

被引:107
作者
Magee, AG
Brzezinska-Rajszys, G
Qureshi, SA
Rosenthal, E
Zubrzycka, M
Ksiazyk, J
Tynan, M
机构
[1] Guys Hosp, Dept Paediat Cardiol, London SE1 9RT, England
[2] Childrens Mem Hosp, Warsaw, Poland
关键词
coarctation; aortic recoarctation; stents;
D O I
10.1136/hrt.82.5.600
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective-To determine the early results of balloon expandable stent implantation for aortic coarctation or recoarctation. Design-Prospective observational study. Setting-Two paediatric cardiology tertiary referral centres. Patients-17 patients, median age 17 years (range 4.4 to 45) and median weight 61 kg (17 to 92). Six had native aortic coarctation and 11 had aortic recoarctation; 14 had upper limb systolic hypertension. Of those with recoarctation, eight had had at least one previous balloon dilatation attempt and two of these patients also had further surgical interventions. Intervention-Balloon expandable Palmaz iliac stent implantation. Main outcome measures-Systolic pressures gradients, minimum aortic diameter, upper limb blood pressures, and incidence of aneurysm formation. Results-18 stents were implanted during 18 procedures in the 17 patients. Mean peak systolic pressure gradient fell from 26 mm Hg (95% confidence interval (CI), 21 to 31 mm Hg) before to 5 mm Hg (2 to 8 mm Hg) after stent implantation (p < 0.001), and mean minimum aortic diameter increased from 7 mm (95% CI, 6 to 8 mm) before to 11.3 mm (10 to 12.6 mm) after implantation (p < 0.001). Complications occurred in five patients (bleeding in two, stent migration in two, and aneurysm formation in one). Two patients remained borderline hypertensive and eight were receiving antihypertensive treatment at most recent assessment. Conclusions-Stent implantation for aortic recoarctation and native coarctation gives good immediate results. Careful follow up is necessary to evaluate complications and the long term effect on blood pressure.
引用
收藏
页码:600 / 606
页数:7
相关论文
共 35 条
[1]   DETERMINANTS OF HEMODYNAMIC-RESULTS OF BALLOON DILATION OF AORTIC RECOARCTATION [J].
ANJOS, R ;
QURESHI, SA ;
ROSENTHAL, E ;
MURDOCH, I ;
HAYES, A ;
PARSONS, J ;
BAKER, EJ ;
TYNAN, M .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (06) :665-671
[2]   LATE DEVELOPMENT OF DISSECTING ANEURYSM FOLLOWING BALLOON ANGIOPLASTY OF NATIVE AORTIC COARCTATION [J].
AYDOGAN, U ;
DINDAR, A ;
GURGAN, L ;
CANTEZ, T .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1995, 36 (03) :226-229
[3]  
BALAJI S, 1991, BRIT HEART J, V65, P100
[4]   Abdominal aortic aneurysms: Preliminary technical and clinical results with transfemoral placement of endovascular self-expanding stent-grafts [J].
Blum, U ;
Langer, M ;
Spillner, G ;
Mialhe, C ;
Beyersdorf, F ;
BuitragoTellez, C ;
Voshage, G ;
Duber, C ;
Schlosser, V ;
Cragg, AH .
RADIOLOGY, 1996, 198 (01) :25-31
[5]   AORTIC-ANEURYSM AFTER PATCH AORTOPLASTY REPAIR OF COARCTATION - A PROSPECTIVE ANALYSIS OF PREVALENCE, SCREENING-TESTS AND RISKS [J].
BROMBERG, BI ;
BEEKMAN, RH ;
ROCCHINI, AP ;
SNIDER, AR ;
BANK, ER ;
HEIDELBERGER, K ;
ROSENTHAL, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (03) :734-741
[6]  
Bulbul ZR, 1996, CATHETER CARDIO DIAG, V39, P36, DOI 10.1002/(SICI)1097-0304(199609)39:1<36::AID-CCD7>3.3.CO
[7]  
2-Z
[8]  
CHEATHAM J, 1998, CARDIOLOGY YOUNG S1, V9, P11
[9]   BALLOON ANGIOPLASTY OF NATIVE COARCTATION OF THE AORTA - MIDTERM FOLLOW-UP AND PROGNOSTIC FACTORS [J].
FLETCHER, SE ;
NIHILL, MR ;
GRIFKA, RG ;
OLAUGHLIN, MP ;
MULLINS, CE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (03) :730-734
[10]   BALLOON ANGIOPLASTY OF COARCTATION OF THE AORTA EVALUATED WITH INTRAVASCULAR ULTRASOUND IMAGING [J].
HARRISON, JK ;
SHEIKH, KH ;
DAVIDSON, CJ ;
KISSLO, KB ;
LEITHE, ME ;
HIMMELSTEIN, SI ;
KANTER, RJ ;
BASHORE, TM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :906-909