Evaporative light-scattering detection in the quantitative analysis of semivolatile polycyclic aromatic compounds by high-performance liquid chromatography

被引:18
作者
Cebolla, VL
Membrado, L
Vela, J
Ferrando, AC
机构
[1] Depto. de Procesos Químicos, Instituto de Carboquímica, CSIC, 50015 Zaragoza, Calle Poeta Luciano Gracia
关键词
D O I
10.1093/chromsci/35.4.141
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Polycyclic aromatic compounds (PACs) with molecular weights lower than 300 were not considered in the past to be analyzable using an evaporative light-scattering detector (ELSD) due exclusively to their supposed volatility. We demonstrate that a variety of small, low-boiling, 3-6-ringed PACs (which include condensed PAHs, heteronuclear polycyclic compounds, and hydroxy-PAHs) can be analyzed using ELSD under mild working conditions without significant volatilization. Although area counts versus sample load can be linearized with adequate regression coefficients in the mass range studied, results obtained from the injection of pure and binary mixtures of PACs indicate that ELSD behaves nonlinearly at low sample loads, regardless of the volatility or involatility of each compound. Quite uniform response factors are obtained on the linear zone for the studied PACs, and analyses of mixtures are carried out with errors generally lower than 6%. Experimental data are better fitted to logarithmic regressions, which provide similar slopes for the studied PACs, which in turn suggest that ELSD operates in similar scattering domains for these compounds under our working conditions. The use of a mathematical simulation of particle size distributions after nebulization and evaporation confirms this and explains why response factors of PACs are similar.
引用
收藏
页码:141 / 150
页数:10
相关论文
共 24 条
[1]  
ASMUS PA, 1984, J CHROMATOGR, V316, P461
[2]   EVAPORATIVE ANALYZER AS A MASS DETECTOR IN THE SIZE-EXCLUSION CHROMATOGRAPHY OF COAL EXTRACTS [J].
BARTLE, KD ;
TAYLOR, N ;
MULLIGAN, MJ ;
MILLS, DG ;
GIBSON, C .
FUEL, 1983, 62 (10) :1181-1185
[3]  
BECART J, 1990, HRC-J HIGH RES CHROM, V13, P126
[4]  
BRULE B, 1978, LAB PONTS CHAUSSEES, V76
[5]   EVAPORATIVE ANALYZER AS A MASS DETECTOR FOR LIQUID-CHROMATOGRAPHY [J].
CHARLESWORTH, JM .
ANALYTICAL CHEMISTRY, 1978, 50 (11) :1414-1420
[6]  
COULOMBE S, 1988, J CHROMATOGR SCI, V26, P1
[7]  
DREUX M, 1992, ANALUSIS, V20, P587
[8]  
Dreux M., 1996, LC GC INT, V9, P146
[9]  
JOHNSON BR, 1995, PREPR AM CHEM SOC DI, V40, P457
[10]  
Kerker M., 1969, The Scattering of Light