Modulator design two-dimensional for comprehensive gas chromatography:: Quantitative analysis of polyaromatic hydrocarbons and polychlorinated biphenyls

被引:67
作者
Hyotyläinen, T [1 ]
Kallio, M [1 ]
Hartonen, K [1 ]
Jussila, M [1 ]
Palonen, S [1 ]
Riekkola, ML [1 ]
机构
[1] Univ Helsinki, Dept Chem, Analyt Chem Lab, FIN-00014 Helsinki, Finland
关键词
D O I
10.1021/ac0201528
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel cryogenic modulator was constructed for comprehensive two-dimensional gas chromatography (GCxGC). The modulator is based on two-step cryogenic trapping with CO2 and thermal desorption with electric heating. The GC x GC system, included a nonpolar first-dimension column and two semipolar second-dimension columns, one connected to a flame ionization detector and the other one to a electron capture detector. A Matlab-based program, which, allowed determination of peak heights and volumes, was written: for the data analysis. The GCxGC system was,applied for the analysis, of polyaromatic hydrocarbons and polychlorinated biphenyls. The functioning of, the modulator and the quantitativity of the method were studied with both peak volumes. and peak heights from a three-dimensional plot. The separate peak areas from the modulated chromatogram were calculated as a comparison. The:quantitative,results were compared with those obtained with the same system but without the thermal modulation. The method was found to be repeatable and linear with use of peak volumes as well as peak heights. There was also good. agreement with the results obtained by integration, of separate peak areas. The developed GC x GC method was applied to the analysis of a, Soxhlet extract of, a certified sediment sample. The results were compared with the certified values.
引用
收藏
页码:4441 / 4446
页数:6
相关论文
共 35 条
[1]   Moving cryogenic modulator for the comprehensive two-dimensional gas chromatography (GC x GC) of surface water contaminants [J].
Beens, J ;
Dallüge, J ;
Adahchour, M ;
Vreuls, RJJ ;
Brinkman, UAT .
JOURNAL OF MICROCOLUMN SEPARATIONS, 2001, 13 (03) :134-140
[2]   Simple, non-moving modulation interface for comprehensive two-dimensional gas chromatography [J].
Beens, J ;
Adahchour, M ;
Vreuls, RJJ ;
van Altena, K ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2001, 919 (01) :127-132
[3]  
Beens J, 1998, HRC-J HIGH RES CHROM, V21, P47
[4]  
DALLUGE JJ, IN PRESS J CHROMAT A
[5]  
de Geus HJ, 2000, HRC-J HIGH RES CHROM, V23, P189
[6]   Characterisation of fatty acids in biological oil samples using comprehensive multidimensional gas chromatography [J].
de Geus, HJ ;
Aidos, I ;
de Boer, J ;
Luten, JB ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2001, 910 (01) :95-103
[7]   Development of a thermal desorption modulator for gas chromatography [J].
deGeus, HJ ;
deBoer, J ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 1997, 767 (1-2) :137-151
[8]  
Dimandja JMD, 2000, HRC-J HIGH RES CHROM, V23, P208, DOI [10.1002/1521-4168(20000301)23:3<208::AID-JHRC208>3.0.CO
[9]  
2-I, 10.1002/(SICI)1521-4168(20000301)23:3&lt
[10]  
208::AID-JHRC208&gt