Ultrawide band multifrequency high-field EMR technique: A methodology for increasing spectroscopic information

被引:309
作者
Hassan, AK
Pardi, LA
Krzystek, J
Sienkiewicz, A
Goy, P
Rohrer, M
Brunel, LC
机构
[1] Florida State Univ, Ctr Interdisciplinary Magnet Resonance, Nat High Magnet Field Lab, Tallahassee, FL 32310 USA
[2] Polish Acad Sci, Inst Phys, PL-02668 Warsaw, Poland
[3] Ecole Normale Super, Dept Phys, Lab Kastler Brossel, F-75231 Paris 05, France
关键词
broadband high-field EMR spectroscopy;
D O I
10.1006/jmre.1999.1952
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report methodology that combines an ultrawide band multifrequency microwave system with technology of high magnetic fields for solving challenging problems in electron magnetic resonance (EMR) spectroscopy. This strategy has been made possible due to a novel EMR facility operating in an exceptionally wide range of microwave frequencies of 24 GHz to 3 THz, at magnetic fields up to 17 T, and in the temperature range of 1.6 to 330 K, The basic configuration of the multifrequency system works in a transmission mode and employs oversized cylindrical waveguides for routing the microwave power. A wide-band, low-noise, liquid helium cooled (4.2 K) InSb bolometer is used for signal detection, This approach results in an extremely wide-band performance, thus making it possible to employ a variety of solid-state millimeter and submillimeter microwave sources in combination with a far infrared laser microwave source for performing multifrequency EMR experiments. A complexity of resonant structures and related technical problems such as microphonics at high magnetic fields is virtually eliminated. The system is simple, yet sensitive, and has been revealed to be extremely advantageous while solving such problems as observation of AFMR transitions in spin-ordered systems, g-factor resolution enhancement in complex organic radicals, and resonance signal detection in EMR-silent spin systems having integer spin and large zero field splitting. A technical description of the multifrequency high-field EMR facility is presented and results of its performance tests are given, The potential utility of using the multifrequency high-field methodology in EMR studies is illustrated with selected examples of its recent applications. (C) 2000 Academic Press.
引用
收藏
页码:300 / 312
页数:13
相关论文
共 53 条
  • [1] ALLGEIER J, 1990, MODERN PULSED CONTIN
  • [2] A novel probe head for high-field, high-frequency electron paramagnetic resonance
    Annino, G
    Cassettari, M
    Longo, I
    Martinelli, M
    Van Bentum, PJM
    Van der Horst, E
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (03) : 1787 - 1793
  • [3] HIGH-FREQUENCY EPR-SPECTRA FOR THE ANALYSIS OF MAGNETIC-ANISOTROPY IN LARGE MAGNETIC CLUSTERS
    BARRA, AL
    CANESCHI, A
    GATTESCHI, D
    SESSOLI, R
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1995, 117 (34) : 8855 - 8856
  • [4] High-frequency EPR spectra of a molecular nanomagnet: Understanding quantum tunneling of the magnetization
    Barra, AL
    Gatteschi, D
    Sessoli, R
    [J]. PHYSICAL REVIEW B, 1997, 56 (13): : 8192 - 8198
  • [5] Submillimeter high-field EPR studies of the primary donor in plant photosystem I P700
    Bratt, PJ
    Rohrer, M
    Krzystek, J
    Evans, MCW
    Brunel, LC
    Angerhofer, A
    [J]. JOURNAL OF PHYSICAL CHEMISTRY B, 1997, 101 (47) : 9686 - 9689
  • [6] Recent developments in high frequency high magnetic field CW EPR. Applications in chemistry and biology
    Brunel, LC
    [J]. APPLIED MAGNETIC RESONANCE, 1996, 11 (3-4) : 417 - 423
  • [7] A NOVEL HIGH-FIELD HIGH-FREQUENCY EPR AND ENDOR SPECTROMETER OPERATING AT 3 MM WAVELENGTH
    BURGHAUS, O
    ROHRER, M
    GOTZINGER, T
    PLATO, M
    MOBIUS, K
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 1992, 3 (08) : 765 - 774
  • [8] Parallel polarization EPR characterization of the Mn(III) center of oxidized manganese superoxide dismutase
    Campbell, KA
    Yikilmaz, E
    Grant, CV
    Gregor, W
    Miller, AF
    Britt, RD
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1999, 121 (19) : 4714 - 4715
  • [9] Quasioptical design for an EPR spectrometer based on a horizontal-bore superconducting solenoid
    Cardin, JT
    Kolaczkowski, SV
    Anderson, JR
    Budil, DE
    [J]. APPLIED MAGNETIC RESONANCE, 1999, 16 (02) : 273 - 292
  • [10] A PULSED EPR AND ENDOR SPECTROMETER OPERATING AT 95 GHZ
    DISSELHORST, JAJM
    VANDERMEER, H
    POLUEKTOV, OG
    SCHMIDT, J
    [J]. JOURNAL OF MAGNETIC RESONANCE SERIES A, 1995, 115 (02) : 183 - 188