Immobilization of GOD on electrochemically synthesized Ppy-PVS composite film by cross-linking via glutaraldehyde for determination of glucose

被引:57
作者
Gade, V. K. [1 ]
Shirale, D. J. [1 ]
Gaikwad, P. D. [1 ]
Savale, P. A. [1 ]
Kakde, K. P. [1 ]
Kharat, H. J. [1 ]
Shirsat, M. D. [1 ]
机构
[1] Marathwada Univ, Dept Phys, Sensor Res Lab, Aurangabad 431004, Maharashtra, India
关键词
immobilization; composite film; glucose-oxidase; cross-linking; biosensor;
D O I
10.1016/j.reactfunctpolym.2006.04.005
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The Ppy-PVS-GOD biosensor for determination of glucose has been described. The enzyme, glucose oxidase (GOD) was immobilised by cross-linking via glutaraldehyde on a polypyrrole-polyvinyl sulphonate (Ppy-PVS) composite film. The Ppy-PVS film was electrochemically synthesized on indium-tin-oxide (ITO)-coated glass plate. We have synthesized Ppy-PVS film with 0.1 M pyrrole, 0.025 M PVS at 3.0 pH and 1 mA/cm(2) current density. The immobilization was done by cross-linking 2 mg/ml GOD via 0.1% glutaraldehyde at 0.1 M phosphate buffer with 7.0 pH. The synthesized composite films were characterized using galvanostatic electrochemical technique, electrical conductivity, UV-Vis spectroscopy, Fourier transform infrared spectroscopy (FT-IR), and scanning electron microscopy (SEM). The cross-linking of enzyme and porous morphology of the polymer film leads to high enzyme loading and an increase in lifetime, stability and fast response time of the enzyme electrode. Amperometric response was measured as a function of different concentration of glucose. It was observed that current increases with increasing glucose concentration in the range 1-50 mM. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1420 / 1426
页数:7
相关论文
共 44 条
[1]   Conducting polymers and the bioanalytical sciences: New tools for biomolecular communications - A review [J].
Adeloju, SB ;
Wallace, GG .
ANALYST, 1996, 121 (06) :699-703
[2]   Electrochemical deposition of polyaniline-polypyrrole composite coatings on aluminum [J].
Akundy, GS ;
Rajagopalan, R ;
Iroh, JO .
JOURNAL OF APPLIED POLYMER SCIENCE, 2002, 83 (09) :1970-1977
[3]  
BARD AJ, 1980, ELECTROCHEMICAL METH, V96
[4]   Characterisation and analytical use of a polypyrrole electrode containing anti-human serum albumin [J].
Barisci, JN ;
Hughes, D ;
Minett, A ;
Wallace, GG .
ANALYTICA CHIMICA ACTA, 1998, 371 (01) :39-48
[5]  
BOWERS LD, 1976, ANAL CHEM, V48, pA545
[6]   POLARONS, BIPOLARONS, AND SOLITONS IN CONDUCTING POLYMERS [J].
BREDAS, JL ;
STREET, GB .
ACCOUNTS OF CHEMICAL RESEARCH, 1985, 18 (10) :309-315
[7]  
BRIGHT HJ, 1969, J BIOL CHEM, V244, P3625
[8]  
CHEN C, 1834, ANAL CHEM, V71, P1999
[9]   Biosensors based on immobilization of biomolecules by electrogenerated polymer films -: New perspectives [J].
Cosnier, S .
APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2000, 89 (2-3) :127-138
[10]   ELECTROCHEMISTRY OF CONDUCTING POLYPYRROLE FILMS [J].
DIAZ, AF ;
CASTILLO, JI ;
LOGAN, JA ;
LEE, WY .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1981, 129 (1-2) :115-132