First Evaluation of the WASP, a New Automated Microbiology Plating Instrument

被引:38
作者
Bourbeau, Paul P. [1 ]
Swartz, Brandi Lynn [1 ]
机构
[1] Geisinger Med Ctr, Div Lab Med, Danville, PA 17822 USA
关键词
D O I
10.1128/JCM.01963-08
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Many laboratories are experiencing growing shortages of trained microbiology technologists and technicians. Consequently, there is considerable interest in new automation that could potentially lessen labor demands for specimen processing. In this study, we present the first published evaluation of a new microbiology instrument, the Walk Away Specimen Processor (WASP), manufactured by Copan, Inc., in which we evaluated cross-contamination, the accuracy of plating, and the quality of the results. The absence of cross-contamination was demonstrated by plating a total of 200 alternating inoculated and sterile specimen tubes. The ability of the WASP to subculture enrichment broths was evaluated with 106 Lim broth specimens, with the results being identical to those obtained by testing by routine methods. Plating of urine specimens with the WASP was compared to plating with the Dynacon Inoculab instrument. Three hundred specimens were plated in duplicate on both instruments with 1-mu l loops, and 293 specimens were plated in duplicate on both instruments with 10-mu l loops. The results of duplicate plating with the same instrument (replicate plating) and of the consensus agreement between the two instruments were compared. The replicate plating results were comparable for both instruments, while the WASP had more specimens with significant results than the Inoculab with the 1-mu l loop only. Lastly, for the plating of 113 specimens in ESwab tubes, the manual method and WASP plating each yielded 90 potential pathogens. In summary, we report the first evaluation of a new microbiology specimen-plating instrument, the WASP, which offers opportunities for the automated plating of microbiology specimens to an extent that has not been possible to date.
引用
收藏
页码:1101 / 1106
页数:6
相关论文
共 7 条
[1]   ACCURACY OF CALIBRATED-LOOP TRANSFER [J].
ALBERS, AC ;
FLETCHER, RD .
JOURNAL OF CLINICAL MICROBIOLOGY, 1983, 18 (01) :40-42
[2]   Evaluation of an automated instrument for inoculating and spreading samples onto agar plates [J].
Glasson, J. H. ;
Guthrie, L. H. ;
Nielsen, D. J. ;
Bethell, F. A. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (04) :1281-1284
[3]  
JONES GA, 2008, 108 GEN M AM SOC MIC
[4]  
KASS EH, 1956, T ASSOC AM PHYSICIAN, V69, P56
[5]  
Lue YA, 2002, 102 GEN M AM SOC MIC
[6]   DIAGNOSIS OF COLIFORM INFECTION IN ACUTELY DYSURIC WOMEN [J].
STAMM, WE ;
COUNTS, GW ;
RUNNING, KR ;
FIHN, S ;
TURCK, M ;
HOLMES, KK .
NEW ENGLAND JOURNAL OF MEDICINE, 1982, 307 (08) :463-468
[7]  
TILTON RC, 1978, J CLIN MICROBIOL, V7, P298