Energy cost of walking and running at extreme uphill and downhill slopes

被引:383
作者
Minetti, AE
Moia, C
Roi, GS
Susta, D
Ferretti, G
机构
[1] Ctr Med Univ Geneva, Dept Physiol, CH-1211 Geneva 4, Switzerland
[2] Manchester Metropolitan Univ, Dept Exercise & Sport Sci, Ctr Biophys & Clin Res Human Movement, Alsager ST7 2HL, Cheshire, England
[3] Federat Sport Altitude, Med Comm, I-13900 Biella, Italy
关键词
gradients; exercise; optimum path; maximum running speed;
D O I
10.1152/japplphysiol.01177.2001
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The costs of walking (Cw) and running (Cr) were measured on 10 runners on a treadmill inclined between -0.45 to +0.45 at different speeds. The minimum Cw was 1.64 +/- 0.50 J.kg(-1).m(-1) at a 1.0 +/- 0.3 m/s speed on the level. It increased on positive slopes, attained 17.33 +/- 1.11 J.kg(-1).m(-1) at +0.45, and was reduced to 0.81 +/- 0.37 J.kg(-1).m(-1) at -0.10. At steeper slopes, it increased to reach 3.46 +/- 0.95 J.kg(-1).m(-1) at -0.45. Cr was 3.40 +/- 0.24 J.kg(-1).m(-1) on the level, independent of speed. It increased on positive slopes, attained 18.93 +/- 1.74 J.kg(-1).m(-1) at +0.45, and was reduced to 1.73 +/- 0.36 J.kg(-1).m(-1) at -0.20. At steeper slopes, it increased to reach 3.92 +/- 0.81 J.kg(-1).m(-1) at -0.45. The mechanical efficiencies of walking and running above +0.15 and below -0.15 attained those of concentric and eccentric muscular contraction, respectively. The optimum gradients for mountain paths approximated 0.20-0.30 for both gaits. Downhill, Cr was some 40% lower than reported in the literature for sedentary subjects. The estimated maximum running speeds on positive gradients corresponded to those adopted in uphill races; on negative gradients they were well above those attained in downhill competitions.
引用
收藏
页码:1039 / 1046
页数:8
相关论文
共 27 条
[1]  
ABBOTT BC, 1952, J PHYSIOL-LONDON, V117, P380, DOI 10.1113/jphysiol.1952.sp004755
[2]   METABOLIC AND MECHANICAL ASPECTS OF FOOT LANDING TYPE, FOREFOOT AND REARFOOT STRIKE, IN HUMAN RUNNING [J].
ARDIGO, LP ;
LAFORTUNA, C ;
MINETTI, AE ;
MOGNONI, P ;
SAIBENE, F .
ACTA PHYSIOLOGICA SCANDINAVICA, 1995, 155 (01) :17-22
[3]   ENERGY EXPENDITURE IN LEVEL AND GRADE WALKING [J].
BOBBERT, AC .
JOURNAL OF APPLIED PHYSIOLOGY, 1960, 15 (06) :1015-1021
[4]   THE ENERGY-COST OF RUNNING INCREASES WITH THE DISTANCE COVERED [J].
BRUECKNER, JC ;
ATCHOU, G ;
CAPELLI, C ;
DUVALLET, A ;
BARRAULT, D ;
JOUSSELIN, E ;
RIEU, M ;
DIPRAMPERO, PE .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1991, 62 (06) :385-389
[5]   EFFECT OF DOWNHILL RUNNING ON MOTONEURON POOL EXCITABILITY [J].
BULBULIAN, R ;
BOWLES, DK .
JOURNAL OF APPLIED PHYSIOLOGY, 1992, 73 (03) :968-973
[6]   SOURCES OF EXTERNAL WORK IN LEVEL WALKING AND RUNNING [J].
CAVAGNA, GA ;
THYS, H ;
ZAMBONI, A .
JOURNAL OF PHYSIOLOGY-LONDON, 1976, 262 (03) :639-657
[7]   LIMITING FACTORS TO OXYGEN-TRANSPORT ON MOUNT EVEREST [J].
CERRETELLI, P .
JOURNAL OF APPLIED PHYSIOLOGY, 1976, 40 (05) :658-667
[8]   PHYSIOLOGICAL-RESPONSES TO RUNNING DOWNHILL [J].
DAVIES, CTM ;
SARGEANT, AJ ;
SMITH, B .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1974, 32 (03) :187-194
[9]  
DICK RW, 1987, MED SCI SPORT EXER, V19, P310