Why don't biologists use SIMS? A critical evaluation of imaging MS

被引:81
作者
Heeren, R. M. A. [1 ]
McDonnell, L. A. [1 ]
Amstalden, E. [1 ]
Luxembourg, S. L. [1 ]
Altelaar, A. F. M. [1 ]
Piersma, S. R. [1 ]
机构
[1] FOM, Inst Atom & Mol Phys, NL-1098 SJ Amsterdam, Netherlands
关键词
ME-SIMS; MALDI; imaging mass spectrometry; time-of-flight mass spectrometry; biomolecules; LASER-DESORPTION IONIZATION; ION MASS-SPECTROMETRY; SUBCELLULAR-LOCALIZATION; SPATIAL-RESOLUTION; GOLD CLUSTERS; STATIC SIMS; TISSUE; DESORPTION/IONIZATION; BOMBARDMENT; PEPTIDES;
D O I
10.1016/j.apsusc.2006.02.134
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Secondary ion mass spectrometry is commonly used to study many different types of complex surfaces. Yet, compared with MALDI and ESI-MS, SIMS has not made a significant impact in biological or biomedical research. The key features of the technique, namely high spatial resolution, high detection efficiency of ions spanning a wide m/z range, surface sensitivity and the high scan rates seem to match ideally with several questions posed at the cellular level. To this date, SIMS has had only limited success in the biological arena. Why is this and what is needed to change this? This discussion paper will critically review the advances and the usefulness of SIMS in biomedical research and compare it to other approaches that offer spatially resolved molecular information available to a researcher with a biological interest. We will demonstrate that the type of information generated by the various incarnations of SIMS is strongly dependent on sample preparation and surface condition and these phenomena are only poorly understood. Modern approaches such as the cluster gun developments, ME-SIMS, gold coating and MALDI stigmatic imaging on a SIMS instrument might change the perception of SIMS being a tool for semiconductor manufacturers and physicists, and might persuade biologists to use these innovative mass spectrometric imaging tools. (c) 2006 Published by Elsevier B.V.
引用
收藏
页码:6827 / 6835
页数:9
相关论文
共 61 条
[1]   Metal-assisted secondary ion mass spectrometry: Influence of Ag and Au deposition on molecular ion yields [J].
Adriaensen, L ;
Vangaever, F ;
Gijbels, R .
ANALYTICAL CHEMISTRY, 2004, 76 (22) :6777-6785
[2]   Mass spectrometry-based proteomics [J].
Aebersold, R ;
Mann, M .
NATURE, 2003, 422 (6928) :198-207
[3]   Impact desolvation of electrosprayed microdroplets - a new ionization method for mass spectrometry of large biomolecules [J].
Aksyonov, SA ;
Williams, P .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (21) :2001-2006
[4]   Gold-enhanced biomolecular surface imaging of cells and tissue by SIMS and MALDI mass spectrometry [J].
Altelaar, AFM ;
Klinkert, I ;
Jalink, K ;
de Lange, RPJ ;
Adan, RAH ;
Heeren, RMA ;
Piersma, SR .
ANALYTICAL CHEMISTRY, 2006, 78 (03) :734-742
[5]   Direct molecular Imaging of Lymnaea stagnalis nervous tissue at subcellular spatial resolution by mass spectrometry [J].
Altelaar, AFM ;
van Minnen, J ;
Jiménez, CR ;
Heeren, RMA ;
Piersma, SR .
ANALYTICAL CHEMISTRY, 2005, 77 (03) :735-741
[6]   COMPARISON OF POLYATOMIC AND ATOMIC PRIMARY BEAMS FOR SECONDARY ION MASS-SPECTROMETRY OF ORGANICS [J].
APPELHANS, AD ;
DELMORE, JE .
ANALYTICAL CHEMISTRY, 1989, 61 (10) :1087-1093
[7]   IMPACT OF SLOW GOLD CLUSTERS ON VARIOUS SOLIDS - NONLINEAR EFFECTS IN SECONDARY ION EMISSION [J].
BENGUERBA, M ;
BRUNELLE, A ;
DELLANEGRA, S ;
DEPAUW, J ;
JORET, H ;
LEBEYEC, Y ;
BLAIN, MG ;
SCHWEIKERT, EA ;
BENASSAYAG, G ;
SUDRAUD, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1991, 62 (01) :8-22
[8]   Molecular imaging of biological samples: Localization of peptides and proteins using MALDI-TOF MS [J].
Caprioli, RM ;
Farmer, TB ;
Gile, J .
ANALYTICAL CHEMISTRY, 1997, 69 (23) :4751-4760
[9]  
Chandra S, 2002, CLIN CANCER RES, V8, P2675
[10]   Assessing protein patterns in disease using imaging mass spectrometry [J].
Chaurand, P ;
Schwartz, SA ;
Caprioli, RM .
JOURNAL OF PROTEOME RESEARCH, 2004, 3 (02) :245-252