Calculation of absorbed dose of low-energy electron beam by an approximate method

被引:3
作者
Vázquez-Polo, G
Valdivia, HL
Abrego, HC
Mijangos, RR
García, R
机构
[1] Univ Nacl Autonoma Mexico, Inst Fis, Mexico City 01000, DF, Mexico
[2] Inst Nacl Invest Nucl, Mexico City 11801, DF, Mexico
[3] UNISON, Ctr Invest Fis, Hermosillo 83190, Sonora, Mexico
关键词
radiation processing; electron beam; depth-dose curve; algorithm;
D O I
10.1016/S0969-806X(01)00459-5
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this work, we present a simple method to calculate absorbed doses of low-energy electron beams together with an experimental procedure for calibrating the accelerator under certain work conditions. The semi-empirical method is useful for a rapid estimation of depth-dose curve of electron beams, which uses an adjustable parameter factor determined by the least-squares fit from experimental values. Our approach is tested in electron processes on different materials, obtaining reasonable agreement. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:181 / 187
页数:7
相关论文
共 14 条
[1]  
*ASTM, 1993, TECHN COMM PRACT DOS
[2]   ACCELERATOR REQUIREMENTS FOR ELECTRON-BEAM PROCESSING [J].
BECKER, RC ;
BLY, JH ;
CLELAND, MR ;
FARRELL, JP .
RADIATION PHYSICS AND CHEMISTRY, 1979, 14 (3-6) :353-375
[3]  
BERGER MJ, 1982, STOPPING POWER RANGE
[4]  
Bethe HA, 1934, P CAMB PHILOS SOC, V30, P524
[5]  
BRYNJOLFSSON A, 1963, P INT C JAN 14 16 RA, P116
[6]  
GARCIA MPZ, 1993, 4 C AN SOC NUCL MEX, V1, P265
[7]   ENERGY DEPOSITION BY ELECTRON BEAMS AND DELTA RAYS [J].
KOBETICH, EJ ;
KATZ, R .
PHYSICAL REVIEW, 1968, 170 (02) :391-&
[8]  
MCLAUGHLIN WL, 1975, INT J APPL RAD ISO B, V2, P95
[9]  
NELMS AT, 1956, C557 NAT BUR STAND
[10]  
Okabe S., 1974, Oyo Buturi, V43, P909