Effects of Adaptive Section Collimation on Patient Radiation Dose in Multisection Spiral CT

被引:118
作者
Deak, Paul D. [1 ]
Langner, Oliver [1 ]
Lell, Michael [2 ]
Kalender, Willi A. [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, D-91052 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Dept Radiol, D-91052 Erlangen, Germany
关键词
MULTISLICE COMPUTED-TOMOGRAPHY; MONTE-CARLO; PEDIATRIC-PATIENTS; OPTIMIZATION; VALIDATION; ADULT;
D O I
10.1148/radiol.2522081845
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the potential effectiveness of adaptive collimation in reducing computed tomographic (CT) radiation dose owing to z-overscanning by using dose measurements and Monte Carlo ( MC) dose simulations. Materials and Methods: Institutional review board approval was not necessary. Dose profiles were measured with thermoluminescent dosimeters in CT dose index phantoms and in an AldersonRando phantom without and with adaptive section collimation for spiral cardiac and chest CT protocols and were compared with the MC simulated dose profiles. Additional dose measurements were performed with an ionization chamber for scan ranges of 5-50 cm and pitch factors of 0.5-1.5. Results: The measured and simulated dose profiles agreed to within 3%. By using adaptive section collimation, a substantial dose reduction of up to 10% was achieved for cardiac and chest CT when measurements were performed free in air and of 7% on average when measurements were performed in phantoms. For scan ranges smaller than 12 cm, ionization chamber measurements and simulations indicated a dose reduction of up to 38%. Conclusion: Adaptive section collimation allows substantial reduction of unnecessary exposure owing to z-overscanning in spiral CT. It can be combined in synergy with other means of dose reduction, such as spectral optimization and automatic exposure control.
引用
收藏
页码:140 / 147
页数:8
相关论文
共 21 条
[1]   Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey [J].
Brix, G ;
Nagel, HD ;
Stamm, G ;
Veit, R ;
Lechel, U ;
Griebel, J ;
Galanski, M .
EUROPEAN RADIOLOGY, 2003, 13 (08) :1979-1991
[2]   Effective doses in standard protocols for multi-slice CT scanning [J].
Cohnen, M ;
Poll, LW ;
Puettmann, C ;
Ewen, K ;
Saleh, A ;
Mödder, U .
EUROPEAN RADIOLOGY, 2003, 13 (05) :1148-1153
[3]   Validation of a Monte Carlo tool for patient-specific dose simulations in multi-slice computed tomography [J].
Deak, Paul ;
van Straten, Marcel ;
Shrimpton, Paul C. ;
Zankl, Maria ;
Kalender, Willi A. .
EUROPEAN RADIOLOGY, 2008, 18 (04) :759-772
[4]  
*FED OFF RAD PROT, 2005, ANN REP 2005 FED OFF
[5]   System performance of multislice spiral computed tomography [J].
Fuchs, TOJ ;
Kachelriess, M ;
Kalender, WA .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2000, 19 (05) :63-70
[6]  
International Commission on Radiological Protection, 1990, INT COMM RAD PROT PU, V60
[7]  
Kalender W.A., 2005, COMPUT TOMOGR, V2nd
[8]   Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadavers [J].
Kalender, WA ;
Wolf, H ;
Suess, C ;
Gies, M ;
Greess, H ;
Bautz, WA .
EUROPEAN RADIOLOGY, 1999, 9 (02) :323-328
[9]   Technical approaches to the optimisation of CT [J].
Kalender, Willi A. ;
Buchenau, Stefanie ;
Deak, Paul ;
Kellermeier, Markus ;
Langner, Oliver ;
van Straten, Marcel ;
Vollmar, Sabrina ;
Wilharm, Sylvia .
PHYSICA MEDICA, 2008, 24 (02) :71-79
[10]   Application- and patient size-dependent optimization of x-ray spectra for CT [J].
Kalender, Willi A. ;
Deak, Paul ;
Kellermeier, Markus ;
van Straten, Marcel ;
Vollmar, Sabrina V. .
MEDICAL PHYSICS, 2009, 36 (03) :993-1007