Two-photon excitation fluorometric measurement of homogeneous microparticle immunoassay for C-reactive protein

被引:33
作者
Waris, ME
Meltola, NJ
Soini, JT
Soini, E
Peltola, OJ
Hänninen, PE
机构
[1] Univ Turku, Cent Hosp, Inst Biochem, Biophys Lab, FIN-20521 Turku, Finland
[2] Turku Univ, Cent Hosp, Dept Clin Chem, Turku 20520, Finland
关键词
fluorescence; two-photon; multiphoton; immunodiagnostics; microparticle; microbead; microsphere; C-reactive protein;
D O I
10.1016/S0003-2697(02)00256-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Recent developments in infrared laser technology have enabled the design of a compact instrumentation for two-photon excitation microparticle fluorometry (TPX). The microparticles can be used in immunoassays as the antibody-coated solid phase to capture an antigen and then detect it with a fluorescently labeled tracer antibody. Unlike most other methods, TPX technology allows low-volume, homogeneous immunoassays with real-time measurements of assay particles in the presence of a moderate excess of fluorescent tracer. In this study. the TPX assay system was used for the reagent characterization and the measurement of C-reactive protein (CRP) in diluted plasma samples, targeting the assay range useful in infectious disease diagnosis. The pentameric structure of the CRP permitted the optimization of an assay with the lowest detectable concentration of 1 mug/L (7.5 pM) by using a single monoclonal antibody both for capture and as the tracer. With a 1:200 predilution of samples. the measurement range of the assay was 1-150 mg/L. but an additional 1:10 dilution was required for higher concentrations. The TPX method showed a good correlation with the reference result obtained in a routine hospital laboratory, demonstrating the feasibility of the technology for immunodiagnostic applications. (C) 2002 Elsevier Science (USA). All rights reserved.
引用
收藏
页码:67 / 74
页数:8
相关论文
共 18 条
[1]   Topology and structure of the C1q-binding site on C-reactive protein [J].
Agrawal, A ;
Shrive, AK ;
Greenhough, TJ ;
Volanakis, JE .
JOURNAL OF IMMUNOLOGY, 2001, 166 (06) :3998-4004
[2]   2-PHOTON FLUORESCENCE CORRELATION SPECTROSCOPY - METHOD AND APPLICATION TO THE INTRACELLULAR ENVIRONMENT [J].
BERLAND, KM ;
SO, PTC ;
GRATTON, E .
BIOPHYSICAL JOURNAL, 1995, 68 (02) :694-701
[3]  
BLACKBURN GF, 1991, CLIN CHEM, V37, P1534
[4]  
Dahler-Eriksen BS, 1999, CLIN CHEM, V45, P478
[5]   2-PHOTON LASER SCANNING FLUORESCENCE MICROSCOPY [J].
DENK, W ;
STRICKLER, JH ;
WEBB, WW .
SCIENCE, 1990, 248 (4951) :73-76
[6]  
Dietz LJ, 1996, CYTOMETRY, V23, P177
[7]   A new microvolume technique for bioaffinity assays using two-photon excitation [J].
Hänninen, P ;
Soini, A ;
Meltola, N ;
Soini, J ;
Soukka, J ;
Soini, E .
NATURE BIOTECHNOLOGY, 2000, 18 (05) :548-550
[8]   Simultaneous two-photon excitation of distinct labels for dual-color fluorescence crosscorrelation analysis [J].
Heinze, KG ;
Koltermann, A ;
Schwille, P .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (19) :10377-10382
[9]   High throughput screening with multiphoton excitation [J].
Lakowicz, JR ;
Gryczynski, I ;
Gryczynski, Z .
JOURNAL OF BIOMOLECULAR SCREENING, 1999, 4 (06) :355-361
[10]  
Lovgren T, 1997, CLIN CHEM, V43, P1937