Advanced breast biopsy instrumentation: A critique

被引:38
作者
Ferzli, GS [1 ]
Hurwitz, JB [1 ]
Puza, T [1 ]
VanVorstBilotti, S [1 ]
机构
[1] STATEN ISL UNIV HOSP,DEPT SURG,STATEN ISL,NY
关键词
D O I
10.1016/S1072-7515(01)00896-1
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Large-core biopsies or open biopsies with needle localization have been the mainstay of treatment for evaluating nonpalpable mammographic abnormalities. The newly introduced Advanced Breast Biopsy instrumentation (ABBI) system combines digital stereotactic imaging with a highly developed single-use biopsy device to locate and remove a radiographically discovered breast lesion to an accuracy of I mm. Study Design: We conducted a review of the first 58 cases involving the use of the ABBI system. This: article evaluates the accuracy of specimen targeting, the success rate of lesion removal, the operative complications, the mechanical difficulties, and patient satisfaction with the ABBI system. Results: The lesion was removed successfully in 47 of the 58 cases. Nine patients were eliminated in initial screening and the procedure could not be completed in two. Although the success rate was high, 14 of the procedures required conversion to ''open'' ABBI procedures for completion of the biopsy. Conclusions: The ABBI system is an alternative to open biopsy with needle localization or large-core biopsy for nonpalpable mammographic abnormalities. This technique allows complete removal of the lesion in a onestep procedure. The ABBI system has certain limitations and mechanical problems, at least currently, and offers an advantage over current diagnostic modalities in a very limited number of cases only. (C) 1997 by the American College of Surgeons.
引用
收藏
页码:145 / 151
页数:7
相关论文
共 13 条
[1]   STEREOTACTIC FINE-NEEDLE BIOPSY IN 2594 MAMMOGRAPHICALLY DETECTED NON-PALPABLE LESIONS [J].
AZAVEDO, E ;
SVANE, G ;
AUER, G .
LANCET, 1989, 1 (8646) :1033-1036
[2]  
DOWLATSHAHI K, 1987, ARCH SURG-CHICAGO, V122, P1343
[3]  
DOWLATSHAHI K, 1989, RADIOLOGY, V170, P424
[4]  
Fine RE, 1996, AM SURGEON, V62, P96
[5]  
HASSELGREN PO, 1993, SURGERY, V114, P836
[6]   SPRING HOOKWIRE BREAST LESION LOCALIZER - USE WITH RIGID-COMPRESSION MAMMOGRAPHIC SYSTEMS [J].
KOPANS, DB ;
LINDFORS, K ;
MCCARTHY, KA ;
MEYER, JE .
RADIOLOGY, 1985, 157 (02) :537-538
[7]  
LANDERCASPER J, 1987, SURG GYNECOL OBSTET, V164, P399
[8]  
NORTON LW, 1988, AM J SURG, V23, P29
[9]   NONPALPABLE BREAST-LESIONS - STEREOTAXIC AUTOMATED LARGE-CORE BIOPSIES [J].
PARKER, SH ;
LOVIN, JD ;
JOBE, WE ;
BURKE, BJ ;
HOPPER, KD ;
YAKES, WF .
RADIOLOGY, 1991, 180 (02) :403-407
[10]   PERCUTANEOUS LARGE-CORE BREAST BIOPSY - A MULTIINSTITUTIONAL STUDY [J].
PARKER, SH ;
BURBANK, F ;
JACKMAN, RJ ;
AUCREMAN, CJ ;
CARDENOSA, G ;
CINK, TM ;
COSCIA, JL ;
EKLUND, GW ;
EVANS, WP ;
GARVER, PR ;
GRAMM, HF ;
HAAS, DK ;
JACOB, KM ;
KELLY, KM ;
KILLEBREW, LK ;
LECHNER, MC ;
PERLMAN, SJ ;
SMID, AP ;
TABAR, L ;
TABER, FE ;
WYNN, RT .
RADIOLOGY, 1994, 193 (02) :359-364