Heterogeneity within MALDI samples as revealed by mass spectrometric imaging

被引:158
作者
Garden, RW
Sweedler, JV
机构
[1] Univ Illinois, Dept Chem, Urbana, IL 61801 USA
[2] Univ Illinois, Beckman Inst, Urbana, IL 61801 USA
关键词
D O I
10.1021/ac9908997
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
While matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) has revolutionized the manner by which many large molecules are characterized, the highly variable appearance of MALDI mass spectra remains a concern, We have developed MALDI-based imaging as a diagnostic tool for examining the relationships between preparation strategy, sample morphology, and spectral quality. The imaging protocol involves the automated acquisition of mass spectra at 400-1600 positions within a single sample, followed by off-line processing and image display. Several sample types have been characterized, including a simple peptide mixture prepared in dried droplets of 2,5-dihydroxybenzoic acid and in thin films of alpha-cyano-4-hydroxycinnamic acid as well as a complex biological sample consisting of intact peptidergic neurons from the marine mollusk Aplysia californica, Imaging experiments provide a wealth of unbiased information concerning sample defects, spectral reproducibility, mass accuracy, differential analyte distributions, and the validity of internal standards.
引用
收藏
页码:30 / 36
页数:7
相关论文
共 44 条
  • [1] Preparation of 'near' homogeneous samples for the analysis of matrix-assisted laser desorption ionisation processes
    Allwood, DA
    Perera, IK
    Perkins, J
    Dyer, PE
    Oldershaw, GA
    [J]. APPLIED SURFACE SCIENCE, 1996, 103 (03) : 231 - 244
  • [2] Amado FML, 1997, RAPID COMMUN MASS SP, V11, P1347, DOI 10.1002/(SICI)1097-0231(199708)11:12<1347::AID-RCM974>3.0.CO
  • [3] 2-8
  • [4] Arnold RJ, 1998, RAPID COMMUN MASS SP, V12, P630, DOI 10.1002/(SICI)1097-0231(19980529)12:10<630::AID-RCM206>3.3.CO
  • [5] 2-S
  • [6] Burlingame AL, 1998, ANAL CHEM, V70, p647R
  • [7] Molecular imaging of biological samples: Localization of peptides and proteins using MALDI-TOF MS
    Caprioli, RM
    Farmer, TB
    Gile, J
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (23) : 4751 - 4760
  • [8] Use of binary solvent systems in the MALDI-TOF analysis of poly(methyl methacrylate)
    Chen, HR
    Guo, BC
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (21) : 4399 - 4404
  • [9] Influence of matrix solution conditions on the MALDI-MS analysis of peptides and proteins
    Cohen, SL
    Chait, BT
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (01) : 31 - 37
  • [10] Confocal fluorescence microscopic imaging for investigating the analyte distribution in MALDI matrices
    Dai, YQ
    Whittal, RM
    Li, L
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (15) : 2494 - 2500